OEM Best overload relay testing Factories – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises. Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr... -
OEM Best power transformer testing Suppliers – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot
Picture only for reference first. GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation. It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc. Features ● 12inch LCD display, with portable design, rugged and durable, easy to use. ● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environmen... -
China High Quality Ac Hipot Test Set Exporters – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot
GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t... -
OEM Best insulation testers Factories – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply... -
China High Quality battery tester price Manufacturer – GDKH-10 Battery Activator – HV Hipot
General Information In all operating equipment and operating network systems with increasing informationization and automation, uninterrupted power supply is the most basic guarantee. Whether it is AC or DC uninterruptible power supply system, the battery acts as backup power source plays an important role in power source system. Usually, the battery is in the state of floating charge standby. Once the AC power is lost or other accidents, the battery becomes the sole energy supplier of the load. We know that in addition to the normal life cycle of the battery, some of the early failure of the battery may occur due to problems such as the quality of the battery itself, defects in materials, structures, processes, and improper use. In order to verify the standby time and actual capaci... -
OEM Best electrical earth tester Manufacturers – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot
General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me... -
OEM Best Hv Impulse Generator Exporters – GDB-D Transformer Turn Ratio Tester – HV Hipot
General Information GDB-D Transformer turn ratio tester is designed for three phases transformer in power system and especially for Z type winding transformer and other transformers with relatively large no-load current. The instrument is with wide range, fast testing speed, favorable repeatability, flexible date processing, convenient connection, perfect protection, easy learning and convenient operation. Features ● Applicable to Z type winding transformer. ● Two output voltage can be optional and able to test transformers with relatively large no-load current. ● With wide range, the highest turn ratio may reach 10000. ● Automatically calculate the tap position. ● Fast testing speed which is only 18s for three phases ● Favorable repeatability. ● Automatically record 99 data at ... -
OEM Best Voltage Pulse Generator Supplier – GDCL-20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot
Application The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments. The device uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing. Standards ● GB 18802.1-2012 GB 18802.1-2012 Surge protective devices connected to low-voltage power distribution systems Par... -
OEM Best digital insulation tester Factory – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply... -
OEM Best Capacitance Is Measured By Factories – PD free Variable Frequency Test System – HV Hipot
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply. Features ● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and po... -
OEM Best dew point meter manufacturers Factory – GDOH-II insulating Oil Gas Content Tester – HV Hipot
General Information GDOH-II Insulating Oil Gas Content Tester is a new generation tester adopts imported high accuracy sensor and the newest sensor technology. It is based on the DL423-91 power industry standard and relevant national standards. It is more practical, more stable and reliable in performance, easy to operate and more suitable for the determination of gas content in ultra-high voltage oil-filled equipment. It is an ideal test equipment for laboratory. Features ● The all-metal structure avoids the problems of fragility and poor sealing of the glassware tester. ● The application of high precision and high stability imported differential pressure sensor makes the test data more accurate and repeatable. ● The test circuit contains the sensors that measure atmospheric pre... -
China High Quality harga earth resistance & resistivity tester Factory – Online Insulation Monitoring Device for DC System – HV Hipot
General Information GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance. It does not produce any AC or DC interference signal to busbar, and will not cause the artificial insulation resistance drop. It is suitable for power plants and substations of any voltage level. GDF-5000/OL’s unique stability and anti-distributed capacitance make it more suitable for bus system under complex working conditions, standard instrument structure, compact size, convenient installation and better applicability. GDF-5000/OL has LCD display, full software function control, perfect man-machine interface, easy operation and use. Features ● ...