info@hvhipot.com
English
CN
Home
About Us
HV HIPOT
Team
Honor & Qualification
Business Scope
Our Factory
Products
High Voltage Test Equipment
AC Hipot Test Set
DC Hipot Test Set
AC DC Combination Hipot Test Set
AC Resonant Test System
VLF AC Hipot Test Set
Partial Discharge&Corona Test System
High Voltage Divider
Turn-to-turn Surge Withstand Tester
Partial Discharge Measurement Device
Partial Discharge Analyzer
Partial Discharge Detector
Partial Discharge Online Test
Impulse Voltage and Current Test System
Impulse Voltage Test System
Impulse Current Test System
Composition Wave Test System
Transformer Test Equipment
Transformer Capacitance And Tan Delta Tester
Transformer DC Winding Resistance Tester
Transformer Load And No Load Loss Tester
Transformer Oil BDV Tester
Transformer Oil Tan Delta Tester
Transformer Test Bench
Transformer Turns Ratio Tester(TTR Tester)
Transformer Winding Deformation Tester
CT/PT Measurement And Analysis
SF6 Gas Leak Detection And Analysis
SF6 Gas Density Relay Calibrator
SF6 Gas Leak Detector
SF6 Gas Online Monitoring Device
SF6 Gas Quality Analyzer
SF6 Gas Recycling System
Switch-gear Test Equipment
Circuit Breaker Analyzer
Contact Resistance Tester
DC Power Supply
Primary Current Injection Test Set
Vacuum Switch Interrupter Vacuity Tester
Cable Fault Locating System
Cable And Pipe Locator
Cable Fault Location System
Cable Test Van
Lightning Arrester/Insulator Test Equipment
Insulator Tester
Lightning Arrester Online Test
Lightning Arrester Tester
Ultrasonic Flaw Detector
Relay Protection Tester
Digital Relay Tester
Universal Relay Tester
Insulation & Earth Resistance Tester
Earth Resistance Tester
Insulation Online Test
Insulation Resistance Tester
Phase Detector
Electric Energy Test Equipment
Energy Meter Calibrator
Power Quality Analyzer
Battery Test Equipment
AC And DC Power Supply
Battery Charge&Discharge Tester
Battery Impedance Tester
Lead Acid Battery Regenerator
Oil Test Equipment
Dissolved Gas Chromatograph Analyzer
Oil Acid Tester
Oil Filtration Machine
Oil Flash Point Tester
Oil Freezing Point Tester
Oil Tension Tester
Oil Trace Moisture Tester
Application
Operation Video
Technical Guide
High Voltage Test Equipment
Services
OEM & Customization
Other Intimate Services
News
Typical Case
Customer Visit
Company News
Contact Us
Featured
Home
Featured
OEM Best Dissipation Factor Tan Delta Supplier – Surge Generator for motor – HV Hipot
GDZJ-5S Turn to Turn Surge Withstand Tester GDZJ-5S is used to test turn-to-turn insulation strength of single-phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between interphase, winding phase, or iron core Specifications ● Peak voltage: 500-5000V continuous adjustment ● Peak error: ≤ 5% (1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50HZ ● Power consumption: ≤ 100 W ● Dimension: 480*260*390mm ● Weight: about 24kg
inquiry
detail
OEM Best Universal Relay Tester Exporters – GDJR-200D Single Phase Electronic Thermal Relay Calibrator – HV Hipot
Standard compliance GB/T 14598.15-1998 Electric Relays Part 8: Thermal Electrical Relays DL/T 624-1997 Technical Specification of Test Equipment Based on Micro-computer for Relaying Protection DL/T 846-2004 General Technical Specifications for High Voltage Test Equipments DL/T 596-2005 Preventive Test Code for Electric Power Equipment GB50150-2006 Electrical Equipment Installation Engineering-standard for Hand-over Test of Electric Equipment GB1094.1-GB1094.6-96 Degrees of Protection Provided by Enclosure (IP Code) GB2900 Electro-technical terminology GB/T16927.1~2-1997 High Voltage Test Techniques GB4793-1984 Safety Requirements for Electronic Measuring Apparatus GB191 Packaging-Pictorial Marking for Handling of Goods GB/T.311-1997 Insulation co-ordination for...
inquiry
detail
China High Quality Plastic Pipe Locator Suppliers – GD-2136H Cable Fault Locating System – HV Hipot
GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
inquiry
detail
China High Quality flash point testers Factories – GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator) – HV Hipot
Coulometric Karl Fischer technology is applied to measure precisely trace moisture the measured sample contains.The technology is widely used for accuracy and cheap test cost.The Model GDW-102 measure precisely trace moisture on liquid, solid and gas samples according to the technology. It’s used in electricity, petroleum, chemicals, foods and so on. Features ● Use improved PWM electrolysis circuit to reduce the power dissipation of the instrument. ● High precise measuring electrode signal and circuit detection make the electrolytic end decision quickly and precisely with strong anti-interference ability. ● Use methods of electrolyte blank current compensation and electrolyte balance drift compensation to devise testing result. ● Built in three calculation formula to generate r...
inquiry
detail
OEM Best testing of instrument transformer Factories – GDJF-2006 Partial Discharge Analyzer – HV Hipot
Features ● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy. ● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage. ● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency. ● Big color LCD screen. Large memory, with USB port. ● With anti-false operation function. Automatic adjusting gain during testing and rectifying. ● Anti-interference design. Specifications ● Capacitance range: 6pF-250μF ● Sensitivity: <0.02pc (capacitance at 50pF) ● Am...
inquiry
detail
OEM Best Primary Injection Test Tools Supplier – GDSL-A Seriese Automatic Primary Current Injection Test Set – HV Hipot
Features ● Built-in high configuration industrial control computer, the programmable logic controller (PLC) as the central processor, real-time scan of AC signal, to achieve comprehensive monitoring and closed-loop control, and design password settings management, only the personnel who gets corresponding operation authority, can carry out operation of certain functions. ● Color LCD touch screen. Using intelligent sensor based on field bus technology and realize the full digital data transmission, display operation unit is touch type color LCD screen, full English menu, the interface is clear and intuitive, the operation is simple and convenient. Test without any auxiliary equipment, automatic control, fast, simple and convenient. ● Automatic and manual test mode, with automatic cons...
inquiry
detail
China High Quality earth tester Manufacturers – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot
General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
inquiry
detail
China High Quality pd transformer Suppliers – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot
Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ...
inquiry
detail
China High Quality Cable Fault Location System Factory – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot
Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
inquiry
detail
OEM Best hand held dew point meter Manufacturers – GDZD-601 oil shaker – HV Hipot
Features 1. 240*128 LCD display. 2. Small size, light weight and low noise. 3. Easy operation, control temperature is accurate. Specification 1. Temperature measurement range: 0~120℃ 2. Temperature control range: Room temperature to 110℃ 3. Temperature control method: Digital PID auto control 4. Temperature control accuracy: Room temperature to 50℃, ±0.2℃; 50℃~100℃,±0.3℃; 100~110℃, ±0.5℃ 5. Shaking frequency: 275±3 times/minute 6. Shaking amplitude: 35mm 7. Quantity of samples: Injector 100ml *8pcs; conical flask 250ml *4pcsA 8. Working modes: Chromatography degassing: Constant temperature at 50℃, shaking for 20 mins, static for 10 mins. Water-soluble acid: Constant temperature at 75℃, shaking for 5 mins, static for 0 minute. User defined: Constant temperature 0 to 110℃ at any...
inquiry
detail
China High Quality Hipot Test Of Cable Factory – DC High Voltage Generator GDZG-300 – HV Hipot
Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste...
inquiry
detail
OEM Best Tensile testing machine Manufacturers – GDW-106 Oil Dew Point Tester User’s Guide – HV Hipot
Caution ● The following instructions are used by qualified person to avoid electrical shock. Do not perform any service beyond operation instructions unless you are qualified to do so. ● Don’t operate this device in flammable and moist environment. Keep the surface clean and dry. ● Please make sure the equipment is upright before opening. Don’t drop equipment heavily avoid equipment movement damage. ● Place the equipment in dry, clean, ventilated area free from corrosive gas. Stacking equipment without transit containers is dangerous. ● Panel should be upright during storage. Elevate stored items to protect from moisture. ● Don’t disassemble the instrument without permission, which will affect the warranty of the product. The factory is not responsible for self-dism...