-
China High Quality omicron relay test kit price Exporters – GDJR-200D Single Phase Electronic Thermal Relay Calibrator – HV Hipot
Standard compliance GB/T 14598.15-1998 Electric Relays Part 8: Thermal Electrical Relays DL/T 624-1997 Technical Specification of Test Equipment Based on Micro-computer for Relaying Protection DL/T 846-2004 General Technical Specifications for High Voltage Test Equipments DL/T 596-2005 Preventive Test Code for Electric Power Equipment GB50150-2006 Electrical Equipment Installation Engineering-standard for Hand-over Test of Electric Equipment GB1094.1-GB1094.6-96 Degrees of Protection Provided by Enclosure (IP Code) GB2900 Electro-technical terminology GB/T16927.1~2-1997 High Voltage Test Techniques GB4793-1984 Safety Requirements for Electronic Measuring Apparatus GB191 Packaging-Pictorial Marking for Handling of Goods GB/T.311-1997 Insulation co-ordination for... -
China High Quality Capacitance Bridge Meter Exporters – DC Hipot Test Set GDZG-S – HV Hipot
Features ● Electronic control and tune, easy to operate. ● The date of voltage and current are recorded in the panel, reading without conversion. ● One minute timing and tip function. ● Perfect overvoltage and over-current protection function inside, also zinc oxide overvoltage protection outside, which ensure safety of generator. ● Both control unit and doubler packed with special shockproof aluminum alloy cabinet, easy to move. ● Portable design, suitable for on-site testing. Specifications Items(kV/mA) parameter 50/100 50/120 60/150 60/200 60/300 Output voltage(kV) 50 50 60 60 60 Output current(mA) 100 120 150 200 300 Output power(W) 5000 6000 9000 12000 18000 Voltage measurement error ≤1.0% ±1digit Current measu... -
OEM Best Capacitance Is Measured By Factories – AC Inductance Resonance Test System for CVT – HV Hipot
GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions. -
OEM Best Gas Purity Check Exporters – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot
General Information GDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content. The core component with NDIR sensor produced by European sensor company to test SF6 gas purity, RC sensor produced by Vaisala, Finland to test dew point, NDIR sensor produced by Smartgas, Germany to test SF6 gas decomposition product–CF4. the air sensor adopts itg technology. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application ● SF6 analysis fo power system ● SF6 gas cylinder gas quality test ● Quality test of SF6 gas for recovery and reuse ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ... -
OEM Best Measure Capacitor In Circuit Supplier – High voltage divider GDFR-D1 – HV Hipot
GDFR-D1 series AC/DC Voltage Meter GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit. Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge. ● Small size, light weight, easy to carry in the field work. ● Inner shield anti-interference system. ● The voltage ratio can be customized, suitable for calibration. ● External voltage meter can be connected. Technical Specifications Model No. GDFR-D1-50 GDFR-D1-100 G... -
OEM Best closed cup flash point test device Supplier – GDKS-205 Automatic Flash Point Open Cup Tester – HV Hipot
General Information GDKS-205 automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department. Features ● 320*240 TFT LCD touch screen. ● With high speed signal processor control, reliable and high accuracy. ● One host can control several test furnace to test several samples at one time, which will save testing time. ● Detection, ignition, alarm, cooling, printing, the whole testing process is completed automatically. ● Platinum electric wire or gas ignit... -
OEM Best earth resistivity test equipment Factory – GD3128 Series Insulation Resistance Tester – HV Hipot
General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch... -
China High Quality price of lt&ht megger Exporters – GDHX-9700 Phase Detector – HV Hipot
General Information GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10... -
China High Quality High Voltage Constant Current Pulse Generator Suppliers – GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester – HV Hipot
GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It has features of fast measurement, small size, light weight, large output current, perfect protection functions, good repeat-ability, good anti-interference ability, high accuracy, which make it an ideal equipment for measuring DC resistance of transformer winding and high inductive equipment. Features ● Controlled by high-speed single chip microcomputer, highly automatic and easy to operate. ● Adopts the new power supply technology with multiple current steps and wide measurement range, which is suitable for DC resistance measurement of large and medium-sized transformers. ● Perfect protection functions, able to protect the instrum... -
China High Quality Ct/Pt Tester Factories – GDHG-108A CT/PT Tester – HV Hipot
GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1... -
China High Quality Vacuum Switch Meter Supplier – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an... -
OEM Best Gas Purity Check Exporters – GDP-311IR SF6 Gas Purity Tester (IR Method) – HV Hipot
General Information GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of SF6 gas purity analyzer. Application ● Analysis purity of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● Quality test of SF6 gas for recovery and reuse ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring Features ● Imported high-precision sensors with self-calibration ...