OEM Best decade resistance box Factory – Online Insulation Monitoring Device for DC System – HV Hipot
General Information GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance. It does not produce any AC or DC interference signal to busbar, and will not cause the artificial insulation resistance drop. It is suitable for power plants and substations of any voltage level. GDF-5000/OL’s unique stability and anti-distributed capacitance make it more suitable for bus system under complex working conditions, standard instrument structure, compact size, convenient installation and better applicability. GDF-5000/OL has LCD display, full software function control, perfect man-machine interface, easy operation and use. Features ● ... -
China High Quality Earth Leakage Circuit Breaker Supplier – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-... -
OEM Best High Voltage Instruments Manufacturers – GDOT-100C Insulation Oil Breakdown Tester 100kV – HV Hipot
Features ● LCD screen display. ● Single-chip control, easy to control. ● Wide range watchdog circuit to avoid system halted. ● Unique HV sampling design to make the test data entering into A/D converter directly, to avoid error caused by analog circuit, which will make measurement more accurate. ● Automatic completing all test procedures. ● 1-6 times breakdown voltage value and times will be saved automatically. It will print test results. ● With over-voltage, over-current and short circuit protection. ● Portable design, easy to move. Specifications ● Output voltage: 0-100kV ● Power distortion rate: <1% ● Voltage increasing speed: 2.0kV/s, 3.0kV/s. Error 0.2kV/s. ● Display: Large LCD screen ● Electrode gap: standard 2.5mm ● Capacity: 1.5kVA ● Power input: AC220V± 10%, 50Hz/60Hz... -
OEM Best dew point analyzer Factories – GDCP-510 Oil Freezing Point Tester – HV Hipot
General Information GDCP-510 Low Temperature Freezing Point Tester is compliant with GB/T 510 “Determination of Solidification Point for Petroleum Products” and GB/T 3535 ”Petroleum Products―Determination of Pour Point. “(ISO 3016) It adopts compressor refrigeration, enclosed bath, equipped with tilt bracket and automatic digital display controller, which uses fuzzy control and PID self-tuning technology, performance is more stable. Specification Temperature range Room temperature to -75ºC. Accuracy ±0.1ºC Refrigeration Germany imported sensor, cascade compressor refrigeration, with new type refrigerant, more quickly and environment friendly. Structure Two-slot & four-hole Temperature correction and display based on automati... -
OEM Best flaw detectors Factory – GDJW-40B Wireless Insulator Tester – HV Hipot
General Information GDJW-40B can be used to test the distribution voltages of the charged suspended insulator or the laboratory detection of the suspended insulator, and enable to effectively detect the internal hidden trouble of the insulator, improve the operating reliability of the power grid system, and improve the working efficiency of the line staff who carries out the live testing. This product adopts wireless transmission, the communication distance between detector and hand-held terminal can up to 100m above, Make the measurement process truly safe and reliable, fast and accurate. In addition, the instrument has a very strong anti-interference performance, fully comply with (EMC) standard requirements, adapt to a variety of electromagnetic field interference situation. Fe... -
OEM Best Switch Tester Manufacturer – GDHL-100A Micro-Ohmmeter – HV Hipot
General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance; ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● Multiple test times can be set, which meets various on-site applications; ● Large current output for a long time, burning the switch ... -
China High Quality overcurrent protection relay tester Manufacturers – GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000M Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to “Smart Substation Relay Protection Technical Specifications” and “Smart Substation Technical Guidelines”. It can not only realize the full function test of the optical digital protection device (IEC61850, smart digital station), but also carry out full function test on the traditional protection device (conventional station). GDJB-6000M is a portable new product independently developed through the use of technologies such as embedded real-time operating systems, high-performance embedded processors, and large-scale logic devices, combined with power field conditions and numerous power user experiences. It is widely applicable t... -
China High Quality Test Vacuum Breaker Manufacturers – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an... -
China High Quality Dc Hipot Test Manufacturer – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot
General Information Specifications Input voltage 220V±5%; frequency 50/60Hz±2% Measurement range 0-30kV, continuous adjustment, ±5% Trigger times 6.25 time/s - 50 times/s Waveform rising time 0.1-0.5μS Capacitance error (+0.3) / (-0.1) µs Impulse capacitance 0.01μF -0.1μF Max output energy 60J Power consumption 1000VA Insulation resistance Insulation resistance between power input terminal and tester ≥20MΩ Dielectric strength 1500V/50Hz at 1min, there is no flashing and breakdown for withstand voltage test. Temperature 0-40 degree Relative humidity ≤80% at 40 degree Waveform capacitance deviation ±3% Dimension 650*550*1700mm Weight 100kg Application Turn to turn withstand voltage test ... -
China High Quality testing of transformer Supplier – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time. Specification Hardware ● Processor: high performance intelligent processor. ● Screen: 4.3inch Touch Screen. ● Operation keys: PVE film keyboard. ● Interface: ● 3.5mm stereo headphone interface ● DC LV current charging interface ● USB 2.0 3G wireless network in... -
China High Quality Low Resistance Tester Supplier – GDHL-200A (GDHL-100A) Micro-Ohmmeter new – HV Hipot
General Information GDHL-200A (GDHL-100A) Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance. ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● At 200A, max. test time can reach 1~999s, which meets various on-site applications. ● Large current output for a long tim... -
China High Quality Ct Analyzer China Exporters – GDHG-201P CT/PT Analyzer – HV Hipot
Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of...