info@hvhipot.com
English
CN
Home
About Us
HV HIPOT
Team
Honor & Qualification
Business Scope
Our Factory
Products
High Voltage Test Equipment
AC Hipot Test Set
DC Hipot Test Set
AC DC Combination Hipot Test Set
AC Resonant Test System
VLF AC Hipot Test Set
Partial Discharge&Corona Test System
High Voltage Divider
Turn-to-turn Surge Withstand Tester
Partial Discharge Measurement Device
Partial Discharge Analyzer
Partial Discharge Detector
Partial Discharge Online Test
Impulse Voltage and Current Test System
Impulse Voltage Test System
Impulse Current Test System
Composition Wave Test System
Transformer Test Equipment
Transformer Capacitance And Tan Delta Tester
Transformer DC Winding Resistance Tester
Transformer Load And No Load Loss Tester
Transformer Oil BDV Tester
Transformer Oil Tan Delta Tester
Transformer Test Bench
Transformer Turns Ratio Tester(TTR Tester)
Transformer Winding Deformation Tester
CT/PT Measurement And Analysis
SF6 Gas Leak Detection And Analysis
SF6 Gas Density Relay Calibrator
SF6 Gas Leak Detector
SF6 Gas Online Monitoring Device
SF6 Gas Quality Analyzer
SF6 Gas Recycling System
Switch-gear Test Equipment
Circuit Breaker Analyzer
Contact Resistance Tester
DC Power Supply
Primary Current Injection Test Set
Vacuum Switch Interrupter Vacuity Tester
Cable Fault Locating System
Cable And Pipe Locator
Cable Fault Location System
Cable Test Van
Lightning Arrester/Insulator Test Equipment
Insulator Tester
Lightning Arrester Online Test
Lightning Arrester Tester
Ultrasonic Flaw Detector
Relay Protection Tester
Digital Relay Tester
Universal Relay Tester
Insulation & Earth Resistance Tester
Earth Resistance Tester
Insulation Online Test
Insulation Resistance Tester
Phase Detector
Electric Energy Test Equipment
Energy Meter Calibrator
Power Quality Analyzer
Battery Test Equipment
AC And DC Power Supply
Battery Charge&Discharge Tester
Battery Impedance Tester
Lead Acid Battery Regenerator
Oil Test Equipment
Dissolved Gas Chromatograph Analyzer
Oil Acid Tester
Oil Filtration Machine
Oil Flash Point Tester
Oil Freezing Point Tester
Oil Tension Tester
Oil Trace Moisture Tester
Application
Operation Video
Technical Guide
High Voltage Test Equipment
Services
OEM & Customization
Other Intimate Services
News
Typical Case
Customer Visit
Company News
Contact Us
Featured
Home
Featured
OEM Best Underground Pipe Locator Factories – GD-7018A Optical Fiber Identifier – HV Hipot
The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
inquiry
detail
OEM Best fuel dew point Suppliers – GDFJ-VI Transformer Dissolved Gas Analyzer – HV Hipot
General Information GDFJ-VI Transformer Dissolved Gas Analyzer is a portable gas chromatograph suitable for on-site rapid analysis. It integrates chromatographic detection, analysis and diagnosis in one, as well as micro detector, mini gas source and built-in touch screen computer. It has higher integration, better stability, more delicate shape and more convenient operation than traditional portable oil chromatography. On-site analysis can timely analyze and diagnose transformer fault conditions, making power work simpler and more convenient. The instrument adopts the classical three-detector process, and the analytical data are identical with those of the traditional laboratory chromatograph. The instrument adopts advanced small modular design concept. It has high integration, sma...
inquiry
detail
OEM Best circuit breaker insulation resistance test Supplier – GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot
GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection. The following indicators are used to measure the degree of discharge of electrical equipment: Partial discharge intensity detection: By measuring the discharge signal in a power frequency cycle, the intensity of the partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence. Partial discharge frequency detection: The device measures the discharge signal within a power frequency cycle, extracts the discharge pulses and characterizes the frequency of partial discha...
inquiry
detail
China High Quality Portable Sf6 Leak Detector Manufacturers – GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot
General Information GDQC-16A Gas Vacuum Pumping and Filling Device is mainly used as auxiliary equipment of gas equipment GCBT, GIS, SF6 during installing, debugging and repairing in various power supply companies, power transmission engineering companies, power plants, ultra high voltage transmission, SF6 gas electrical switch manufacturing plant and other departments. It can perform to pump vacuum and fill gas for electric equipment. Features ● Can be moved as a tanker with an armored hose ● Pointer type vacuum display. ● Weighing function. (optional) ● Storage tank heating function. (optional) ● Multi protection-function can ensure safe operation. ● Easy maintenance and high performance. ● Suitable for 10-35kV electrical devices. Technical Specifications Vacuum Pump Ra...
inquiry
detail
OEM Best Pf Capacitor Price Supplier – 50kV AC DC Dielectric Test Equipment GDYD-53D – HV Hipot
Application AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Digital display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm...
inquiry
detail
China High Quality megger insulation tester supplier Factory – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply...
inquiry
detail
OEM Best Micro Ohm Meters Exporters – GDSL-BX-200 Primary Current Injection Test Set – HV Hipot
Features ● Digital control, high anti reference ability. ● Adapts autotransformer regulator which with low power consumption and large capacitance. ● Converter has high permeability core. ● Quick connects, lock design, have good current capability. ● PVC panel. ● Build-in quick plug with high safety. ● Current range can be changed, easy to read. ● Engineering plastics box, IP67 dustproof and waterproof. ● Portable design is suitable for on-site testing. ● Zero start function to prevent the test objects from damage caused by high current impulsing. The equipment only can be started at zero. ● Impulse choosing function: The current value can be outputted directly without zero protection function when the equipment is under the testing for circuit breaker. ● 0-50A AC current can be outp...
inquiry
detail
OEM Best insulation resistance testers Factory – GDHX-9500 Phase Detector – HV Hipot
General Information GDHX-9500 Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector.It uses wireless transmission technology, safe and reliable, fast and accurate, suitable for using at different voltage levels (6V-50...
inquiry
detail
China High Quality flash point analysis Exporters – GDZD-601 oil shaker – HV Hipot
Features 1. 240*128 LCD display. 2. Small size, light weight and low noise. 3. Easy operation, control temperature is accurate. Specification 1. Temperature measurement range: 0~120℃ 2. Temperature control range: Room temperature to 110℃ 3. Temperature control method: Digital PID auto control 4. Temperature control accuracy: Room temperature to 50℃, ±0.2℃; 50℃~100℃,±0.3℃; 100~110℃, ±0.5℃ 5. Shaking frequency: 275±3 times/minute 6. Shaking amplitude: 35mm 7. Quantity of samples: Injector 100ml *8pcs; conical flask 250ml *4pcsA 8. Working modes: Chromatography degassing: Constant temperature at 50℃, shaking for 20 mins, static for 10 mins. Water-soluble acid: Constant temperature at 75℃, shaking for 5 mins, static for 0 minute. User defined: Constant temperature 0 to 110℃ at any...
inquiry
detail
OEM Best Megger 500 volt Manufacturers – GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot
Product Description GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy. The instrument is an integrated structure, built-in variable frequency power supply module, and the output power supply is continuously variable frequency adjustable. The frequency can be changed to 45Hz or 55Hz, and the built-in high-speed processor core adopts high-end digital filtering technology, which effectively avoids the interference of the power frequency electric field to the test, and fundamentally solves the problem of accurate measurement und...
inquiry
detail
OEM Best Insulator tester Supplier – GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester – HV Hipot
Product Description GDYZ-302 Zinc Oxide Arrester Live Tester is a special instrument used to test the electrical performance of Zinc Oxide Arrester. It is suitable for live or power-off detection of Zinc Oxide Arrester of various voltage levels, so that to found dangerous defects such as dampness of internal insulation and aging of valve plates in time. The instrument is simple to operate and easy to use. The entire measurement process is controlled by an industrial computer. It can measure the full current, resistive current and its harmonics, power frequency reference voltage and harmonics, active power and phase difference. Displays true waveforms of voltage and current. The instrument uses digital waveform analysis technology and software anti-interference methods such as harmoni...
inquiry
detail
OEM Best extech insulation tester Factory – GDF-3000A DC System Earth Fault Detector – HV Hipot
General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to detect and locate faults using the DC current difference in the fault loop. The fast FFT transform technology is introduced into the DC fault finding device, to detect various types of insulation faults, DC mutual faults, and AC power failures in DC systems with different voltage level (24V (optiona...
inquiry
detail
<<
< Previous
218
219
220
221
222
223
224
Next >
>>
Page 221 / 278
Send your message to us:
Write your message here and send it to us
Hit enter to search or ESC to close