-
China High Quality Tan Delta Manufacturer – Variable Frequency AC Resonant Test System – HV Hipot
Features ● Small size, light weight, portable design. ● Suitable for 35kV or below cables. ● Single parts not more than 30kg, easy to carry. ● 220V or 380V single phase power supply,convenient for on-site power sourcing. Specifications ● Rated output voltage: based on cable voltage, usually it is 2Uo or 3Uo. ● Output frequency: 20 -300Hz. ● Resonant voltage waveform: sine wave, THD ≤ 1%. ● Full load working time: continuous working time 60mins. ● Quality factor: max. load ≥ 20. ● Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%. ● Power supply: 220V or 380V single-phase. -
China High Quality Circuit Breaker Test Equipment Factory – GDHL-200A (GDHL-100A) Micro-Ohmmeter new – HV Hipot
General Information GDHL-200A (GDHL-100A) Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance. ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● At 200A, max. test time can reach 1~999s, which meets various on-site applications. ● Large current output for a long tim... -
OEM Best Step Pulse Generator Factory – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot
Standards IEC 156: 1995 Insulating liquids- Determination of the breakdown voltage at power frequency Features ● Adopts a microprocessor, three cups in one, and automatically completes the operations of boosting, holding, stirring, standing, calculating, printing, etc., and can perform oil circulation withstand voltage test in the range of 0-100kV. ● LCD screen display. ● The operation of this instrument is simple, the operator only needs to make simple settings, and the instrument will automatically complete the test of 1-3 oil samples according to the settings. For each oil sample, the breakdown voltage value and number of cycles are automatically stored. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil samp... -
China High Quality distribution transformers Supplier – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot
Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ... -
China High Quality Best Cable Locator Factory – GD-2134E Cable Identifier – HV Hipot
GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta... -
China High Quality Miniature Circuit-Breaker Manufacturer – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot
Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece -
China High Quality Dc Coupling Capacitor Suppliers – AC Resonant Test System for Generators GDTL – HV Hipot
GDTL series AC Resonant Test System for Generators can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance. Both two methods can be used to achieve resonance. In the voltage boosting process, if the resonant point deviate, it can be found exactly by the way of fine tuning frequency, which ensure a high Q value and reduce power capacity and volume weight of test equipment. Features ● Smaller size,lighter weight compared with same voltage level,same capacity generator AC withstand voltage test equipment.Single equipment is no more than 60kg, easy to move. ● Advanced principle of whole set device and new frequency & inductance modulation technology, strictly ensure generator power frequency withstand volt... -
OEM Best cable insulation test Supplier – GD3128 Series Insulation Resistance Tester – HV Hipot
General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch... -
OEM Best Testing For Gas Leaks Manufacturers – GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot
General Information GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP® series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer. Application Features Specification SF6 Humidity ● Measurement method: Resistive and Capaci... -
China High Quality Automatic Ct Pt Testing Factory – GDHG-108A CT/PT Tester – HV Hipot
GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1... -
China High Quality dew point gauge Manufacturer – GDW-106 Oil Dew Point Tester User’s Guide – HV Hipot
Caution ● The following instructions are used by qualified person to avoid electrical shock. Do not perform any service beyond operation instructions unless you are qualified to do so. ● Don’t operate this device in flammable and moist environment. Keep the surface clean and dry. ● Please make sure the equipment is upright before opening. Don’t drop equipment heavily avoid equipment movement damage. ● Place the equipment in dry, clean, ventilated area free from corrosive gas. Stacking equipment without transit containers is dangerous. ● Panel should be upright during storage. Elevate stored items to protect from moisture. ● Don’t disassemble the instrument without permission, which will affect the warranty of the product. The factory is not responsible for self-dism... -
OEM Best Simulate Lightning Impulse Manufacturers – GDBT-1000kVA Transformer Test Bench – HV Hipot
General Information Test Object: 22.9kV Single Phase transformers and special transformers, load voltage and current: AC 0-650V/78A, AC 0-1200V/29A, AC 0-2400V/14.6A The impedance of tested transformer is within 7%, HV side is 23kV, 11kV, 6kV. LV side is 0.05kV-2.4kV. This test bench can conduct below test: 1. No-load test including no-load loss, the percent of no-load current to rated current. 2. Load test including load loss, impedance voltage percentage, automatic temperature conversion and load loss test under 30% or above full current. 3. Induced voltage test. Features ● Manual record test data and save in the database. ● The data of No-load test can be corrected by waveform and rated voltage automatically. ● The data of Load test can be corrected by temperature (75℃, 100℃, 1...