Featured

  • OEM Best PT testing kit Factories –  GDCR3000 Digital Earth Resistance Tester – HV Hipot

    OEM Best PT testing kit Factories – GDCR3000 Digital Earth Resistance Tester – HV Hipot

    General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear...
  • OEM Best Earth electrode tester Supplier –  GDF-3000 DC System Earth Fault Detector – HV Hipot

    OEM Best Earth electrode tester Supplier – GDF-3000 DC System Earth Fault Detector – HV Hipot

    General Information In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault. GDF-3000 Earth Fault Tester for DC System locates these earth faults and displays the parameters of system voltage, earth voltage, earth resistance and earth impedance of branches accurately. Functions ● System ground voltage measurement function, the instrument can measure the system ground voltage, negative to ground voltage, system voltage, can achieve 0-300V voltage monitoring range. ● System insulation impedance measurement function, the instrument can measure the positive to ground insulation impedance and the negative to ground insulatio...
  • OEM Best measurement of earth resistance Supplier –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    OEM Best measurement of earth resistance Supplier – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • OEM Best earth resistance tester manufacturers Factory –  GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot

    OEM Best earth resistance tester manufacturers Factory – GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot

    Product Description GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy. The instrument is an integrated structure, built-in variable frequency power supply module, and the output power supply is continuously variable frequency adjustable. The frequency can be changed to 45Hz or 55Hz, and the built-in high-speed processor core adopts high-end digital filtering technology, which effectively avoids the interference of the power frequency electric field to the test, and fundamentally solves the problem of accurate measurement und...
  • OEM Best Partial Discharge Detector Is A Device That Measures Of Detects Manufacturer –  GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    OEM Best Partial Discharge Detector Is A Device That Measures Of Detects Manufacturer – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    Picture only for reference first. GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation. It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc. Features ● 12inch LCD display, with portable design, rugged and durable, easy to use. ● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environmen...
  • OEM Best Routine Test Of Circuit Breaker Exporters –  GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    OEM Best Routine Test Of Circuit Breaker Exporters – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature:  -1...
  • China High Quality alat ukur megger Suppliers –  GDHX-9500 Phase Detector – HV Hipot

    China High Quality alat ukur megger Suppliers – GDHX-9500 Phase Detector – HV Hipot

    General Information GDHX-9500 Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector.It uses wireless transmission technology, safe and reliable, fast and accurate, suitable for using at different voltage levels (6V-50...
  • OEM Best Contact Resistance Test Set Factory –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    OEM Best Contact Resistance Test Set Factory – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-...
  • China High Quality Hipot Factories –  GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

    China High Quality Hipot Factories – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

    General Information Specifications Input voltage 220V±5%; frequency 50/60Hz±2% Measurement range 0-30kV, continuous adjustment, ±5% Trigger times 6.25 time/s - 50 times/s Waveform rising time 0.1-0.5μS Capacitance error (+0.3) / (-0.1) µs Impulse capacitance 0.01μF -0.1μF Max output energy 60J Power consumption 1000VA Insulation resistance Insulation resistance between power input terminal and tester ≥20MΩ Dielectric strength 1500V/50Hz at 1min, there is no flashing and breakdown for withstand voltage test. Temperature 0-40 degree Relative humidity ≤80% at 40 degree Waveform capacitance deviation ±3% Dimension 650*550*1700mm Weight 100kg Application Turn to turn withstand voltage test ...
  • China High Quality analog megger insulation tester Exporters –  Online Insulation Monitoring Device for DC System – HV Hipot

    China High Quality analog megger insulation tester Exporters – Online Insulation Monitoring Device for DC System – HV Hipot

    General Information GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance. It does not produce any AC or DC interference signal to busbar, and will not cause the artificial insulation resistance drop. It is suitable for power plants and substations of any voltage level. GDF-5000/OL’s unique stability and anti-distributed capacitance make it more suitable for bus system under complex working conditions, standard instrument structure, compact size, convenient installation and better applicability. GDF-5000/OL has LCD display, full software function control, perfect man-machine interface, easy operation and use. Features ● ...
  • OEM Best rishabh clamp meter Suppliers –  Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot

    OEM Best rishabh clamp meter Suppliers – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot

    General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me...
  • OEM Best Cable Fault Detector Manufacturer –  GD-2136H Cable Fault Locating System – HV Hipot

    OEM Best Cable Fault Detector Manufacturer – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...