Featured

  • China High Quality how do you test relays Factories –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    China High Quality how do you test relays Factories – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    Features ● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode. ● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information; ● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high cu...
  • China High Quality Capacitor Is Measured In Factory –  Partial Discharge Test System GDYT series – HV Hipot

    China High Quality Capacitor Is Measured In Factory – Partial Discharge Test System GDYT series – HV Hipot

    GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD 2. PD-free Gas type transformer YDQW 3. Coupling capacitor 4. Protective resistor 5. Isolation filter LBQ 6. Partial discharge detector Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic control technology, good anti-interference performan...
  • China High Quality High Voltage Capacitor Bank Suppliers –  AC Inductance Resonance Test System for CVT – HV Hipot

    China High Quality High Voltage Capacitor Bank Suppliers – AC Inductance Resonance Test System for CVT – HV Hipot

    GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions.
  • OEM Best Sf6 Gas Recycling Device Factory –  GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot

    OEM Best Sf6 Gas Recycling Device Factory – GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot

    General Information GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP®  series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer. Application Features Specification SF6 Humidity ● Measurement method: Resistive and Capaci...
  • China High Quality megger can be used for testing Suppliers –  GDF-3000 DC System Earth Fault Detector – HV Hipot

    China High Quality megger can be used for testing Suppliers – GDF-3000 DC System Earth Fault Detector – HV Hipot

    General Information In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault. GDF-3000 Earth Fault Tester for DC System locates these earth faults and displays the parameters of system voltage, earth voltage, earth resistance and earth impedance of branches accurately. Functions ● System ground voltage measurement function, the instrument can measure the system ground voltage, negative to ground voltage, system voltage, can achieve 0-300V voltage monitoring range. ● System insulation impedance measurement function, the instrument can measure the positive to ground insulation impedance and the negative to ground insulatio...
  • China High Quality Gas Leak Detector Supplier Exporters –  GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    China High Quality Gas Leak Detector Supplier Exporters – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    Product Description GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It is a good device suitable for power supply department, installation and overhaul unit, power test institute. Application ● High Voltage Switch Equipment ● Rotor vane of helicopter ● Gas transmission system ● To detect fire extinguisher ● Ventilation efficiency research of Buildings ● To detect danger Advantages ● No radiation. ● No need to replace high pressure high pure argon gas regularly. ● No need to approach high pressure gas. ● No need to replace sensors regularl...
  • China High Quality earth tester supplier Factory –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

    China High Quality earth tester supplier Factory – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

    General Information GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement.The instrument used large caliber current clamp design, can ...
  • OEM Best soil resistivity tester Exporters –  GD2000D Insulation Resistance Tester – HV Hipot

    OEM Best soil resistivity tester Exporters – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...
  • China High Quality Cable Fault Locator Price Manufacturers –  GD-2134E  Cable Identifier – HV Hipot

    China High Quality Cable Fault Locator Price Manufacturers – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...
  • China High Quality Copper Cable Tester Manufacturer –  GD-2136H Cable Fault Locating System – HV Hipot

    China High Quality Copper Cable Tester Manufacturer – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • China High Quality Power Cable Tracer Factory –  GD-2134E  Cable Identifier – HV Hipot

    China High Quality Power Cable Tracer Factory – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...
  • China High Quality Sf6 Gas Analyzer Manufacturers –  GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot

    China High Quality Sf6 Gas Analyzer Manufacturers – GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot

    General Information GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP®  series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer. Application Features Specification SF6 Humidity ● Measurement method: Resistive and Capaci...

Send your message to us:

Write your message here and send it to us