  • OEM Best dissolved gas analysis Suppliers –  GDZD-601 oil shaker – HV Hipot

    OEM Best dissolved gas analysis Suppliers – GDZD-601 oil shaker – HV Hipot

    Features 1. 240*128 LCD display. 2. Small size, light weight and low noise. 3. Easy operation, control temperature is accurate. Specification 1. Temperature measurement range: 0~120℃ 2. Temperature control range: Room temperature to 110℃ 3. Temperature control method: Digital PID auto control 4. Temperature control accuracy: Room temperature to 50℃, ±0.2℃; 50℃~100℃,±0.3℃; 100~110℃, ±0.5℃ 5. Shaking frequency: 275±3 times/minute 6. Shaking amplitude: 35mm 7. Quantity of samples: Injector 100ml *8pcs; conical flask 250ml *4pcsA 8. Working modes:  Chromatography degassing: Constant temperature at 50℃, shaking for 20 mins, static for 10 mins.  Water-soluble acid: Constant temperature at 75℃, shaking for 5 mins, static for 0 minute.  User defined: Constant temperature 0 to 110℃ at any...
  • China High Quality High Voltage Discharge Tool Factory –  AC hipot test set for insulated boom GDYD-137 – HV Hipot

    China High Quality High Voltage Discharge Tool Factory – AC hipot test set for insulated boom GDYD-137 – HV Hipot

    Application Technical Specifications Input AC 220V± 10%, 50Hz, 32.5A, Single phase Output 0-130kV, 50mA   0-36kV, 180mA Rating 25mA/90mA, continuous working 33.3kV/120mA, 1hour ON/1hour OFF 50mA/180mA, 5mins ON/15mins OFF Capacity 6.5kVA HT Source SF6 gas (Gas testing transformer) Output control Manual control Voltage accuracy ≤ 1.5% (F.S) Current Accuracy ≤ 1.5% (F.S) Timing range  0-99H Metering LCD display, kV meter: there is a switching button, the range is 0-36kVAC if it switches to 36kV, the range is 0-130kVAC if it switches to 130kV mA meter: 0-5.000mA  Humidity 85% RH Environmental temperature -20℃~50℃
  • China High Quality Insulation Resistance Tester Manufacturers –  Substation Temperature Monitoring System – HV Hipot

    China High Quality Insulation Resistance Tester Manufacturers – Substation Temperature Monitoring System – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...
  • China High Quality earthing multimeter Exporters –  Substation Temperature Monitoring System – HV Hipot

    China High Quality earthing multimeter Exporters – Substation Temperature Monitoring System – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...
  • China High Quality power transformers Manufacturers –  GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    China High Quality power transformers Manufacturers – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ...
  • OEM Best types of partial discharge Exporters –  GDPD-313M Portable Partial Discharge Detector – HV Hipot

    OEM Best types of partial discharge Exporters – GDPD-313M Portable Partial Discharge Detector – HV Hipot

    External flexible sensor (for option) Parabolic sensor (wave condenser, for option) TEV and AE method is acknowledged and suitable technology to be used in online partial discharge detection. GDPD-313M uses ultrasonic detection technology (AE) and TEV mode, which can effectively ensure signal sensitivity in the interference on-site environment. It is suitable to detect PD flaw and locate PD signal for switch cabinet etc. Features ● Built-in ultrasonic sensor. electrical fault generates ultrasonic wave at the fault point, and ultrasonic mode transmits the ultrasonic signal through the earphone to scan the area to detect the discharge. Various characteristics of vibration, pop, and hum can be associated with different faults. ● Built-in high-precision TEV sensor, coupled with electrom...
  • China High Quality Lightning Impulse Generator Suppliers –  GDZRC series DC Winding Resistance Tester – HV Hipot

    China High Quality Lightning Impulse Generator Suppliers – GDZRC series DC Winding Resistance Tester – HV Hipot

    Features ● Four leads measurement to ensure measuring accuracy. ● Program-controlled current source to increase measuring speed. ● Auto discharge and discharge indication function, to ensure safety and availability. ● LCD screen and Built-in Printer. Specifications Items Specifications Remark Testing current 1mA  10mA  1A  5A  10A   Measurement range 1mA: 10mA: 1A: 5A: 10A: 1Ω-20KΩ 1Ω-2KΩ 10mΩ-20Ω 1mΩ-4Ω 1mΩ-2Ω   GDZRC-20A DC Winding Resistance Tester Testing current 1A  5A  10A  20A Measurement range 1A: 10mΩ~20Ω 5A: 1mΩ~4Ω 10A: 1mΩ~2Ω 20A: 1mΩ~1Ω Weight About 10kg GDZRC series DC Winding Resistance Tester GDZRC-40A Testing current 2.5A  5A  10A  20A  40A Measurement range 2.5A:10mΩ-8Ω 5A: 1mΩ-4Ω 10A: 1mΩ-2Ω 20A: 1mΩ-1Ω 40A:1mΩ-500mΩ W...
  • OEM Best flash point analysis Suppliers –   GDSZ-402 Automatic Acid Value Tester – HV Hipot

    OEM Best flash point analysis Suppliers – GDSZ-402 Automatic Acid Value Tester – HV Hipot

    General Information  Automatic Acid Value Tester is designed for testing acid value for transformer oil, turbine oil and fire resistant oil etc. PC control system can improve the work efficiency and reduce the harm in organic solvents and chemicals to human body. This instrument is easy to operate and have good capacity in anti-interference and stability.  Features ● 320*240 LCD touch screen, user-friendly interface. ● Neutralization titration principle, to complete liquid charge, titrate, stir, determine the titration end point automatically under normal temperature. LCD screen can show the test result and print. ● Color sensor can match up the test titration end point, the judgment of end condition is reliable. ● Waste liquor cup is no need. ● Peristaltic pump control the cha...
  • OEM Best UHF PD DETECTOR Factory –  Partial Discharge Online Monitoring System of GIS – HV Hipot

    OEM Best UHF PD DETECTOR Factory – Partial Discharge Online Monitoring System of GIS – HV Hipot

    General Information Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equi...
  • OEM Best vlf test voltage Factories –  Partial Discharge Online Monitoring System of Generators – HV Hipot

    OEM Best vlf test voltage Factories – Partial Discharge Online Monitoring System of Generators – HV Hipot

    General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n...
  • China High Quality Dc Tester Exporters –  High voltage divider GDFR-D1 – HV Hipot

    China High Quality Dc Tester Exporters – High voltage divider GDFR-D1 – HV Hipot

    GDFR-D1 series AC/DC Voltage Meter GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.  Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge. ● Small size, light weight, easy to carry in the field work. ● Inner shield anti-interference system. ● The voltage ratio can be customized, suitable for calibration. ● External voltage meter can be connected. Technical Specifications Model No. GDFR-D1-50 GDFR-D1-100 G...
  • OEM Best High Voltage Pulse Generator Factory –  GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot

    OEM Best High Voltage Pulse Generator Factory – GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot

    General Information GD6100C Automatic Precision Oil Dielectric Loss Tester, is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument intergrates with test oil cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components.  Features ● The test cell adopts the three-electrode structure according to national standard GB/T5654-2007, with electrode spacing 2mm, which can eliminate the effects of the stray capacitance and leakage on dielectric loss test results. The device is equipped with the oil drainage solenoid switch, and we can empty the test cell without removing it and rinse it wi...