China High Quality Relay testers Manufacturer – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises. Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr... -
China High Quality Capacitor For Transformer Supplier – Partial Discharge Test System GDYT series – HV Hipot
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD 2. PD-free Gas type transformer YDQW 3. Coupling capacitor 4. Protective resistor 5. Isolation filter LBQ 6. Partial discharge detector Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic control technology, good anti-interference performan... -
OEM Best flashpoint obtained under closed cuo condition Manufacturers – GDKS-205 Automatic Flash Point Open Cup Tester – HV Hipot
General Information GDKS-205 automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department. Features ● 320*240 TFT LCD touch screen. ● With high speed signal processor control, reliable and high accuracy. ● One host can control several test furnace to test several samples at one time, which will save testing time. ● Detection, ignition, alarm, cooling, printing, the whole testing process is completed automatically. ● Platinum electric wire or gas ignit... -
China High Quality pd diagnostics Manufacturers – GDJF-2008 Partial Discharge Analyzer – HV Hipot
GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products such as transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation. This type has the advantages of high sensitivity, wide range of capacitance, being well equipped for input unit impedance detecting and more variants of frequency bands (9 in all). After proper setting, the discharge impulse amount can be read directly. The indicating and digital meters are shown simultaneously. This detector is widely applied in power stations, manufacturers, and institutions. Use Condition ● Ambient temperature: 0-40℃±2℃. ● Relative humidity: ≤80% ● Power supply: 220V±10%, 50HZ. ● No violent vibration and mechanical shock. ● Th... -
OEM Best Capacitor Benefits Supplier – Partial Discharge Test System GDYT series – HV Hipot
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD 2. PD-free Gas type transformer YDQW 3. Coupling capacitor 4. Protective resistor 5. Isolation filter LBQ 6. Partial discharge detector Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic control technology, good anti-interference performan... -
OEM Best megger test Supplier – Substation Temperature Monitoring System – HV Hipot
General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f... -
OEM Best relay tester made in china Suppliers – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot
Features ● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode. ● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information; ● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high cu... -
China High Quality High Impedance Fault Suppliers – GD-4138H Cable Fault Locating System – HV Hipot
GD-4138H Mobile Cable Fault Locating System is important tool to maintain all kinds of cables. It is compatible equipment that can trace, locate the underground cables, with fault distance measurement and HV generation. As it is movable device, it is convenient to carry on-site. If acoustic locator is used together, it can locate accurate position of cable fault point. Application is underground cable, aerial cable, power cable, local cable, communication cable and fiber cable. Typical fault to be detected includes ● High impedance flash-over fault ● High impedance leak ● High/low resistive grounding ● Short-circuit fault ● Open-circuit fault ● Poor connection/Disconnection GD-4138L system includes ● GD-4138H main frame (Coupling device, Sphere gap, HV generator are inside) ● GD-... -
China High Quality Ct Pt Testing Factory – GDHG-201P CT/PT Analyzer – HV Hipot
Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of... -
OEM Best Ipec Partial Discharge Manufacturer – Partial Discharge Online Monitoring System of Generators – HV Hipot
General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n... -
OEM Best numerical relay testing Supplier – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot
Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A Adjustable 2. AC current: 0-100A/7V (200A can be customized); 0-20A/25V Adjustable; 0-5A/5V Adjustable 3. DC voltage: 0-220V/3A Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed... -
OEM Best Voltage Testing Equipment Suppliers – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot
Standards IEC 156: 1995 Insulating liquids- Determination of the breakdown voltage at power frequency Features ● Adopts a microprocessor, three cups in one, and automatically completes the operations of boosting, holding, stirring, standing, calculating, printing, etc., and can perform oil circulation withstand voltage test in the range of 0-100kV. ● LCD screen display. ● The operation of this instrument is simple, the operator only needs to make simple settings, and the instrument will automatically complete the test of 1-3 oil samples according to the settings. For each oil sample, the breakdown voltage value and number of cycles are automatically stored. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil samp...