China High Quality Flue Gas Analyzer Manufacturer – GDWS-311RC SF6 Gas Dew Point Tester – HV Hipot
General Information GDWS-311RC is ideal instrument to test dew point of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features ● Better than ±2℃ measurement accuracy. ● All gas path are ... -
China High Quality Current Impulse Generator Exporters – GDCL-10kA Impulse Current Generator – HV Hipot
Working Environment ● Environmental temperature: -10℃ to 40℃ ● Related humidity: ≤ 85% RH ● Altitude: ≤ 1000m ● Indoor use ● No conductive dust, no fire or explosive danger, no corrosive metal or insulation gas. ● Power voltage waveform is sine wave, distortion rate <5% ● Earth resistance is no more than 1Ω. Applied Standard IEC60099-4: 2014 Surge Arresters-Part 4: Metal-oxide surge arresters without gaps for a.c. systems. GB311.1-1997 Insulation coordination of HV Power transmission and transformation. IEC 60060-1 High Voltage Testing Technique- General Testing Requirement. IEC 60060-2 High Voltage Testing Technique- Measurement System. GB/T16896.1-1997 Digital Recorder of High Voltage Impulse Test. DLT992-2006 Implementing Rules for Impulse Voltage Measurement. DL/T613-1997 T... -
OEM Best insulation tester kyoritsu model 3125 Exporters – GDCR3000 Digital Earth Resistance Tester – HV Hipot
General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear... -
China High Quality determine dew point Factories – GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator) – HV Hipot
Coulometric Karl Fischer technology is applied to measure precisely trace moisture the measured sample contains.The technology is widely used for accuracy and cheap test cost.The Model GDW-102 measure precisely trace moisture on liquid, solid and gas samples according to the technology. It’s used in electricity, petroleum, chemicals, foods and so on. Features ● Use improved PWM electrolysis circuit to reduce the power dissipation of the instrument. ● High precise measuring electrode signal and circuit detection make the electrolytic end decision quickly and precisely with strong anti-interference ability. ● Use methods of electrolyte blank current compensation and electrolyte balance drift compensation to devise testing result. ● Built in three calculation formula to generate r... -
China High Quality Testing A Capacitor With A Voltmeter Manufacturer – Surge Generator for motor – HV Hipot
GDZJ-5S Turn to Turn Surge Withstand Tester GDZJ-5S is used to test turn-to-turn insulation strength of single-phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between interphase, winding phase, or iron core Specifications ● Peak voltage: 500-5000V continuous adjustment ● Peak error: ≤ 5% (1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50HZ ● Power consumption: ≤ 100 W ● Dimension: 480*260*390mm ● Weight: about 24kg -
China High Quality use of earth tester Suppliers – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot
General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ... -
China High Quality earth resistance meter Exporters – GDCR3000 Digital Earth Resistance Tester – HV Hipot
General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear... -
China High Quality high voltage test kit Manufacturers – High voltage divider GDFR-D1 – HV Hipot
GDFR-D1 series AC/DC Voltage Meter GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit. Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge. ● Small size, light weight, easy to carry in the field work. ● Inner shield anti-interference system. ● The voltage ratio can be customized, suitable for calibration. ● External voltage meter can be connected. Technical Specifications Model No. GDFR-D1-50 GDFR-D1-100 G... -
China High Quality Miniature Circuit-Breaker Exporters – GDKC-15 Series Circuit Breaker Analyzer – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong anti-interference ability. It ... -
OEM Best Combustion Gas Analyzer Manufacturer – GDIR-1000L SF6 Gas Infrared Imaging Leak Detector – HV Hipot
Product Description GDIR-1000L SF6 Gas Infrared Imaging Leak Detector is a highly technical instrument which is independently developed by our company and has independent intellectual property rights. It is specially used to directly observe the leakage of SF6 gas equipment in the operation of the electric power industry. It uses infrared imaging principle and unique image processing algorithm, to ensure test sensitivity and reducibility of the instrument. Simple and reliable operation, high test sensitivity, the image is intuitionistic and clear, able to find the SF6 gas leakage point of the electrical equipment accurately and quickly. Features ● Infrared imaging detection, visualization. ● Fast Start-up, no need to warm up, and 10 seconds can be put into detection. ● No need for... -
China High Quality use of earth tester Exporters – GDHX-9700 Phase Detector – HV Hipot
General Information GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10... -
OEM Best Handheld Gas Leak Detector Manufacturers – GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot
General Information GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP® series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer. Application Features Specification SF6 Humidity ● Measurement method: Resistive and Capaci...