Featured

  • OEM Best Capacitors For Sale Factories –  PD free Variable Frequency Test System – HV Hipot

    OEM Best Capacitors For Sale Factories – PD free Variable Frequency Test System – HV Hipot

    GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply. Features ● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and power,...
  • OEM Best Ac Voltage Tester Suppliers –  Partial Discharge Test System GDYT series – HV Hipot

    OEM Best Ac Voltage Tester Suppliers – Partial Discharge Test System GDYT series – HV Hipot

    GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD 2. PD-free Gas type transformer YDQW 3. Coupling capacitor 4. Protective resistor 5. Isolation filter LBQ 6. Partial discharge detector Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic control technology, good anti-interference performan...
  • OEM Best Sf6 Gas Detector Exporters –  GDSF-411CPD SF6 Gas Comprehensive Analyzer – HV Hipot

    OEM Best Sf6 Gas Detector Exporters – GDSF-411CPD SF6 Gas Comprehensive Analyzer – HV Hipot

    General Information GDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product. The core component with chilled mirror method is used to test dew point, European sensor with infrared method to test SF6 gas purity and electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Features Specification SF6 Humidity Measurement method Chilled mirror method (Stirling Refrigeration) Measurement range Dew point -100℃–+20℃(90s for single point measurement), error: better than ±0.2℃ Repeat-ability ± 0.1 ℃ Resolution 0.01℃ Display unit ℃, ppm, ℃ P20(convert...
  • China High Quality Ct/Pt Metering Set Manufacturer –  GDHG-106B  CT/PT Analyzer – HV Hipot

    China High Quality Ct/Pt Metering Set Manufacturer – GDHG-106B CT/PT Analyzer – HV Hipot

    Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p...
  • China High Quality overcurrent protection relay tester Suppliers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    China High Quality overcurrent protection relay tester Suppliers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A  Adjustable 2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable 3. DC voltage: 0-220V/3A  Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
  • China High Quality Dc Coupling Capacitor Supplier –  Turn-to-turn Surge Tester – HV Hipot

    China High Quality Dc Coupling Capacitor Supplier – Turn-to-turn Surge Tester – HV Hipot

    GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ...
  • China High Quality Current Transformer 15kv Manufacturer –  GDHG-108A CT/PT Tester – HV Hipot

    China High Quality Current Transformer 15kv Manufacturer – GDHG-108A CT/PT Tester – HV Hipot

    GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1...
  • OEM Best Primary Current Injection Test Manufacturer –  GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot

    OEM Best Primary Current Injection Test Manufacturer – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot

    Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers...
  • OEM Best testing of instrument transformer Exporters –  Partial Discharge Online Monitoring System of Generators – HV Hipot

    OEM Best testing of instrument transformer Exporters – Partial Discharge Online Monitoring System of Generators – HV Hipot

    General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n...
  • OEM Best Pulse Generator Price Supplier –  GDZRC series DC winding resistance tester GDZRC-20U – HV Hipot

    OEM Best Pulse Generator Price Supplier – GDZRC series DC winding resistance tester GDZRC-20U – HV Hipot

    Application ● Welding quality of winding contact ● Turn-to-turn short circuit of winding ● Contact of tap changer Features ● 320*240dot matrix, 65k true color LCD display. ● High speed single chip control, high automation degree, easy operation. ● With sound discharge alarm, discharge indication is clear. ● Fast response speed. The tap changer can be converted directly in measurement status. The instrument update data automatically. ● Four leads measurement to ensure measuring accuracy. ● With clock and power-off storage. Save up to 1000groups test data. ● With RS232 and USB port, which can communicate with PC and for USB disk storage. Specifications ● Output current: <20mA, 1A, 2.5A, 5A, 10A, 20A ● Min. Resolution: 0.1μΩ ● Range: 100μΩ-1Ω (20A)                    500μΩ-2Ω (...
  • OEM Best electrical resistivity meter Supplier –  GDF-3000A  DC System Earth Fault Detector – HV Hipot

    OEM Best electrical resistivity meter Supplier – GDF-3000A DC System Earth Fault Detector – HV Hipot

    General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to detect and locate faults using the DC current difference in the fault loop. The fast FFT transform technology is introduced into the DC fault finding device, to detect various types of insulation faults, DC mutual faults, and AC power failures in DC systems with different voltage level (24V (optiona...
  • OEM Best Capacitor Measurement Suppliers –  AC DC High Voltage Divider – HV Hipot

    OEM Best Capacitor Measurement Suppliers – AC DC High Voltage Divider – HV Hipot

    GDFR-C1 series AC/DC Voltage Meter GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument. Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● The voltage ratio can be customized, suitable for calibration. ● Upside down is forbidden when installation. Technical Specifications Model No. GDFR-C1-50 GDFR-C1-100 GDFR-C1-150 GDFR-C1-200 GDFR-C1-300 GDFR-C1-400 Voltage(kV) 50 100 150 200 300 400 DC frequency (Hz) <2 AC frequency (Hz) 30-300 Accuracy AC: 1.5%/DC: 1.0% Accuracy for option (G type) AC: 1.0%/DC: 0.5% –...