GD-610C Remote Ultrasonic Partial Discharge Detector

GD-610C Remote Ultrasonic Partial Discharge Detector

Brief Description:

The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the sound of signals to diagnose faults, it is a diagnosis device for the accident of the distribution line.

 


Product Detail

Product Tags

GD-610CRemote Ultrasonic Partial Discharge Detector
Features

● Long-distance non-contact charging detection, laser accurate positioning, maximum detection distance up to 30 meters, and support low-speed vehicle inspection. It can be tested on vehicles with a speed of 30km/h.
● Efficient "inspection qualified" type insulation state inspection tool, light weight, easy to carry, especially suitable for live detection of outdoor transmission lines.
● Handheld ultrasonic detectors with high sensitivity, strong directionality and directivity, and can accurately locate hidden faults of the line.
● The handheld ultrasonic detector can be used independently, or it can be connected to the main display wirelessly when needed.
● Flashlight-style appearance, light weight and easy to carry; host can connect with mobile phone and headset wireless, great convenient for site maintenance.
● The patrol instrument supports real-time communication with mobile phones and tablets and can synchronize the collected real-time data to the cloud to truly realize front-end detection and rear-view analysis. (Some functions need to be customized)
● After the device host is connected to the mobile phone, the main interface of the APP displays the partial discharge amplitude (dB), the time domain analysis waveform, and the partial discharge columnar statistical graph.
● The electrical equipment fault point generates a partial discharge signal, through the wireless bluetooth headset can accurately hear the fault sound in real time. The vibrational, popping, humming, and humming sounds of various features can be associated with different faults.
● The earphone can monitor and locate the partial discharge condition, and the volume of the earphone can be adjusted at any time on the mobile phone.
● Mobile phone downloads the Android APP and matches with the host, and uses the “AE Tracker” inspection background software to conveniently collect, manage and store data.
● Using rechargeable lithium battery power supply, can ensure that the equipment continues to work for more than 8 hours.
● Ultrasonic testing can be applied to the noise environment and is not affected by environmental sounds. It is an indispensable professional inspection tool for power supply line inspection personnel.
● Don't need to be powered off during the detection process.
● It Can also detect partial discharges of power equipment such as cable terminations, motors, and dry-type transformers.

Specifications

Software

System

Android 8.0.0

Memory

4.0GB

Function

data display, chart display

Storage

64GB

Take Photo

support

Ultrasonic sensor

Measurement range

-7dB~60dB

Resolution

1dB

Accuracy

±1dB

Sensitivity

-65dB

Sensor center frequency

40.0±1.0KHz

Sensor bandwidth

2.0KHz

Battery

Built-in battery

Lithium battery, 8.4V, 3500mAh

Use time

About 8 hours

Charging time

Approx. 5 hours

Battery protection

Over voltage and over current protection

Battery charger

Rated voltage

8.4V

Charging output current

2A

Working temperature

-20℃-60 ℃

Working humidity

<80%

Hardware

Housing

Monochrome molding plastic

Screen

Wireless display (Android phone or tablet)

Control

Start/stop button

Interface

Charger interface; headphone interface;

Headphones

High fidelity noise reduction wired headset; wireless Bluetooth headset

Size

Instrument size: 380mm * 30mm

Instrument box size: 395mm * 295mm * 105mm

Weight

Instrument weight: 0.5KG

Instrument with box weight: 2.3KG

The weight of whole set of equipment: 2.7KG

Working environment

Operating temperature: -20 ℃ ~ 50 ℃

Ambient humidity: 0-90%RH

IP rating: 54