GDHG-108A CT/PT Analyzer

GDHG-108A CT/PT Analyzer

Brief Description:

GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. 


Product Detail

Product Tags

GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection.

Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT.

Features

● Using the voltage detection principle to measure CT and PT.
● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards.
● No external auxiliary equipment, a single machine can complete all test items.
● With high speed micro printer: real-time print the test result.
● Using intelligent controller, operation is simple.
● 5inch LCD screen display.
● Automatically given CT/PT (excitation) knee point value.
● Auto display 5% and 10% error curve.
● Save 3000 groups data, it won't lost after power off.
● With USB port. The data can be saved in USB disk and read by PC (WORD format file). 
● Light weight, less than 22kg, suitable for onsite testing.

Specifications

Main functions

CT (voltage detection) PT
• Voltage current characteristic curve (excitation characteristic) • Voltage current characteristic curve (excitation characteristic)
• Auto calculate knee point value • Auto calculate knee point value
• Auto display 5% and 10% error curve • Turns ratio measurement
• Turns ratio measurement • Polarity determination
• Polarity determination • AC Hipot Test
• AC Hipot Test • Demagnetization of iron core
• Demagnetization of iron core • Voltage multiple can be adjusted (1.2-2.5times) in PT VA characteristic test
• Accurate limit factor(ALF) measurement  

Main parameters 

Item Parameter
Power supply AC220V±10%, 50Hz
Output 0-1000Vrms(20A peak)
Accuracy of excitation measurement ≤ 0.4% of the reading+0.6% of the range
CT turns ratio measurement Range ≤3000A/1A(15000A/5A)
Accuracy ±1.0%
PT turns ratio measurement Range ≤500KV
Accuracy ±1.0%
Operation environment Temperature: -10℃ ~ 40℃, humidity: ≤90%, Altitude: ≤1000m
Dimension&Weight Dimension: 440mm × 360mm × 340mm   Weight: ≤22Kg
Accessories
CT/PT Tester 1piece
Test Lead 1set
Earth cable 1piece
Power cord 1piece
2A fuse 2pcs
User's guide 1copy
Factory test report 1copy

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us