GDJW-40B Wireless Insulator Tester

GDJW-40B Wireless Insulator Tester

Brief Description:

GDJW-40B can be used to test the distribution voltages of the charged suspended insulator or the laboratory detection of the suspended insulator, and enable to effectively detect the internal hidden trouble of the insulator, improve the operating reliability of the power grid system, and improve the working efficiency of the line staff who carries out the live testing.

 


Product Detail

Product Tags

General Information

GDJW-40B can be used to test the distribution voltages of the charged suspended insulator or the laboratory detection of the suspended insulator, and enable to effectively detect the internal hidden trouble of the insulator, improve the operating reliability of the power grid system, and improve the working efficiency of the line staff who carries out the live testing. This product adopts wireless transmission, the communication distance between detector and hand-held terminal can up to 100m above, Make the measurement process truly safe and reliable, fast and accurate. In addition, the instrument has a very strong anti-interference performance, fully comply with (EMC) standard requirements, adapt to a variety of electromagnetic field interference situation.

Features

● Operating voltage: 35-1000KV, different voltage levels are applicable.
● Voltage Measuring range: 0-40kV (special voltage can be customized).
● Measurement error: ≤±1%.
● Sampling rate: 10 times/S.
● Date time settings: adjust the date and time, to facilitate users to browse, view historical data.
● Back-light time settings: constant bright, constant off, 0-999 minutes can be set up.
● Auto power off settings: never, 0-999 minutes can be set up.
● The transmission distance of hand-held terminal and detector is ≤100m.
● Multi-mode design, powerful applicability, more secure and convenient.
● Universal joint design, enable to flexibly adjust the direction of measurement according to the suspension position of the insulator string.
● Double shielded, strong anti-interference ability, fully comply with EMC standards.
● Unique man-machine interface, easy to operate.

Specifications
Voltage measuring range 0-40kV (special voltage can be customized)
Measuring error ±1%
Resolution 0.01kV
Sampling rate 10 times/S
Working current ≤120mA (Hand-held terminal), ≤40mA (Detector)
Power supply 2*1.5V AA dry battery (Hand-held terminal)
2*1.5V AAA dry battery (Detector)
Sustainable working time ≥12h
Transmission distance ≥100m (adequate power supply)
Display LCD display, can be clearly displayed under sunlight.
Working temperature -35℃---+60℃
Storage temperature -40℃---+65℃
Relative humidity ≤90% RH  Non-condensate
Accessories
No. Basic configuration Unit Qty. Remark
1 Hand-held terminal set 1  
2 Dedicated detector piece 1  
3 A, B Detector root 2  
4 AA Dry battery (1.5V) section 2  
7 AAA Dry battery (1.5V) section 2  
8 Import portable case piece 1  
9 220kV Insulation rod root 1 ≤220kV match with 4secttions 4M insulation rod, ≥330kV match with 6 sections 6M insulation rod
10 Operation manual copy 1  
11 Test report copy 1  
12 Warranty card copy 1  
13 Packing list copy 1  

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Products categories

    Send your message to us:

    Write your message here and send it to us