GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

Brief Description:

There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.


Product Detail

Product Tags

Features

● It adopts a microprocessor to automatically complete the operations of boosting, holding, stirring, static, calculating, printing, etc., and can perform oil circulation withstand voltage test in the range of 0-80 kV.
● Large LCD touch screen. Chinese and English interchangeable menu prompts; beautiful appearance and small size.
● The instrument is easy to operate, the operator only needs to make a simple setting, and the instrument will automatically complete the withstand voltage test of 1 cup of oil sample according to the setting. The breakdown voltage value and the number of cycles of 1 to 10 times are automatically stored. After the test is completed, the thermal printer can print out the breakdown voltage values and average values.
● Instrument test execution standards include industry standards, national standards and IEC60156 standards, and the operation is simple and convenient.
● With power-down hold, 100 experimental results can be stored and the current ambient temperature and humidity can be displayed.
● With over-voltage, over-current, limit and other protection to ensure the safety of operators.
● With temperature measurement display function and system clock display.
● Standard RS232 interface, can communicate with the computer.
● USB interface, can export test data.

Specifications
 Output voltage: 0-80kV(optional)
 Power distortion rate:  <3%
 Capacity:  1.5kVA
 Measurement accuracy:  ±3%
 Stop boosting voltage:  10~80kV adjustable
 Static time:  0-15 minutes adjustable
 Voltage increasing interval time:  0-5 minutes adjustable
 Stirring time:  0-120 seconds adjustable or continuously
 Voltage increasing times:  1-10 times adjustable
 Voltage increasing rate:  0.5kV/s-5.0kV/s adjustable
 Power input:  AC220V± 10%, 50Hz/60Hz±1Hz
 Power:  200W
 Working temperature:  0-45℃
 Humidity:  <75%RH
 Dimension: 460*280*320mm

 

Accessories
GDOT-80A instrument 1pc
Oil cup 1pc
Power cord 1pc
Ground cable 1pc
Spare fuse 2pcs
Elbow 2pcs
Standard gauge 1pc
Hexagon wrench 1pc
Tweezers 2pcs
Stirring nut 2rolls
Print paper 1pc
User's guide 1pc
Factory test report 1pc

 


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us