GDTF-4500kVA/750kV Variable Frequency AC Resonant Test System | Series Resonant Withstand Voltage Tester for GIS & Switchgear

GDTF-4500kVA/750kV Variable Frequency AC Resonant Test System | Series Resonant Withstand Voltage Tester for GIS & Switchgear

Brief Description:

GDTF-4500/750 is specially designed for AC withstand voltage test for 500kV or below switch, GIS, instrument transformers and neutral point of main transformers.

 The system includes Variable frequency power supply, exciting transformer, reactor, and capacitive voltage divider.


Product Detail

Product Tags

Features

•  With the protection function of over-voltage, over-current, zero-start, system detune (flashover). Over-voltage, over-current protection value can be set accordingly to user’s need. Flashover protection starts when flashover and the flashover voltage value will be recorded for testing analysis.

•  The unit piece of the device is light, suitable for field use.

•  There are three kinds of working mode for user choosing according to on-site condition.

Automatic mode, Manual mode, Automatic tuning manual boosting mode.

•   Data can be stored, and the stored data No. are figures which is easy for identification and searching.

•   Frequency starting point can be set in the specified scope when the device sweep frequency automatically, sweep frequency direction can be selected upward or downward, meanwhile LCD displays the scanning curve, which is convenient to know if the resonant point found or not intuitively.

•   With DSP technology, which can increase or decrease functions and updated accordingly to the user’s need, it also makes the human-machine interface more friendly.

Specifications
  1. Output voltage waveform distortion rate: <1.0%.
  2. Allowing continuous working time: one-time 5mins at rated value.
  3. Quality factor of the equipment: Q>50
  4. Quality factor of making test for firepower generator: Q>10 (Related with load).
  5. Quality factor of making test for power cable: Q>30 (Related with load)
  6. Quality factor of making test for main transformers: Q>30 (Related with load)
  7. Quality factor of GIS, circuit breakers in full load test: Q > 50 (Related with load)
  8. Input power supply: Two phase 380V.
  9. Frequency adjusting range: 20-300Hz.
  10. System measurement accuracy: 1.5%.
  11. Over-voltage, over-current, zero-start protection.