MRT-10 Portable 10kV Insulation Resistance Tester for Transformer & Cable Diagnostic Testing

MRT-10 Portable 10kV Insulation Resistance Tester for Transformer & Cable Diagnostic Testing

Brief Description:

MRT-10 High Voltage Insulation Resistance Tester is a professional instrument developed and produced by HV HIPOT in accordance with IEC 61010-1 and other relevant standards. It is used to measure the insulation resistance of power transformers, cables, motors, lines and materials. It uses high-voltage DC injection technology to output a stable DC voltage to the device under test through an internal precision high-voltage generator, accurately measuring the leakage current and automatically calculating the insulation resistance value. 


Product Detail

Product Tags

Features

• Covers IR/DAR/PI/DD/SV full-function test modes, and realizes dual-mode calculation of DAR absorption ratio.

•The three-in-one operation matrix of key control, touch screen, and knob mouse simplifies the operation link to the extreme, making the test more flexible and faster.

• Multi-level voltage range can be switched arbitrarily, and custom voltage mode is supported.

• Real-time recording and visualization of insulation resistance-voltage-current time curve, supporting transient analysis of insulation state.

• With AC and DC voltage measurement function, it can automatically identify voltage type and measure AC frequency.

•With cable length measurement function, equipped with controllable hardware and software filters, the anti-interference performance is significantly improved.

• Three safety barriers, including independent discharge circuit, sample breakdown protection and arc detection, not only protect the equipment safety, but also accurately lock the insulation weak points to prevent accidents.

•High and low voltage circuit full isolation architecture to ensure the safety of operators.

• With USB storage function, data can be exported to USB flash drive in batches for easy backup and migration. 

Specifications

Test Voltage

100V, 250V, 500V, 1000V, 2500V, 5000V, 10000V

Full-scale resistance value corresponding

to the test voltage

200GΩ, 500GΩ, 1.00TΩ, 2.00TΩ, 5.00TΩ, 10.0TΩ, 20.0TΩ

Custom test voltage

50V-10000V, minimum step  10V; when using rotating mouse to control, the step value automatically switches between 10V, 100V, and 200V with the speed, and the higher the speed, the larger the step.

Voltage

output accuracy

0%~+10%

 

Resistance range and resolution

0-9.99kΩ 0.01kΩ; 10.0-99.9kΩ 0.1kΩ;

100-999kΩ 1kΩ; 1.00-9.99MΩ 10kΩ;

10.0-99.9MΩ 100kΩ; 100-999MΩ 1MΩ;

1.00-9.99GΩ 10MΩ; 10.0-99.9GΩ 100MΩ;

100-999GΩ 1GΩ; 1.0-9.99TΩ 10GΩ;

10.0-20.0TΩ 100GΩ.

Short circuit current

1mA-6mA, adjustable, step 1mA

Accuracy: ±5%, continuous output power: 55W.

Test time

10 seconds to 99 minutes adjustable
Voltage measurement AC/DC 10V-660V, ± (2%+3 digits)
AC voltage frequency 25Hz-85Hz, resolution 0.1Hz, accuracy ±0.2Hz
Capacitance measurement  

10nF-25μF, test voltage ≥100V, accuracy: ±10%±5nF

Capacitance test

sample discharge rate

 

From 10kV to 50V, ≤0.47s/μF

AC power supply 85-264Vrms, 50/60Hz, 65VA
Built-in battery 16.8V, 4400mAH lithium battery
Built-in charger 16.8V, 2.3A
Battery life 10kV@100MΩ load, about 5 hours
Use temperature -10℃~50℃
Relative humidity <90%, no condensation.
Dimensions 320mm*280mm*200mm

Weight

About 4.2kg
Voltage measurement AC/DC 10V-660V, ± (2%+3 digits)
AC voltage frequency 25Hz-85Hz, resolution 0.1Hz, accuracy ±0.2Hz

 


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us