OEM Best methodology in relay testing Factory – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot
OEM Best methodology in relay testing Factory – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot Detail:
Features
A. Working conditions
1. Power supply: AC 220V±10%,50Hz
2. Working environment: Temperature -10℃~40℃; Humidity: ≤85%
3. Atmosphere: 86-106kPa
B. Output power supply
1. AC voltage: 0-220V/3A Adjustable
2. AC current: 0-100A/7V (200A can be customized); 0-20A/25V Adjustable; 0-5A/5V Adjustable
3. DC voltage: 0-220V/3A Adjustable
4. DC current:0-20A/25V
5. Fixed voltage output: DC 24V/48V/110V/220V
6. Current/Voltage accuracy: ±1%.
C. Performance Index
1. Ammeter and voltmeter: 41/2 digit.
2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms.
D. Functions
1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay.
2. Time relay: Measure start value, return value and action time.
3. Intermediate relay: Measure all kinds of coil with start. Remain start value, return value, holding value and action time of coil intermediate relay.
4. Reclosing relay: Charge test of capacitance, charge time, reclosing time and middle components test.
5. Differential relay: DC Excitation test, Braking test, Volt-ampere characteristic test.
6. Other common relays and LV circuit breaker.
Accessories
| Name | Qty |
| GDJB-II secondary injection test set | 1 pc |
| Power cable | 1 pc |
| Test line | 6 pcs |
| Current line | 2 pcs |
| Fuse | 4 pcs |
| Manual | 1 copy |
| Certificate | 1 copy |
Product detail pictures:
Related Product Guide:
High quality Very first,and Shopper Supreme is our guideline to offer the most beneficial company to our clients.Nowadays, we're hoping our best to be certainly one of the top exporters in our area to satisfy consumers additional will need for OEM Best methodology in relay testing Factory – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot , The product will supply to all over the world, such as: Bulgaria, Ukraine, Australia, Our aim is to help customers realize their goals. We have been making great efforts to achieve this win-win situation and sincerely welcome you to join us. In a word, when you choose us, you choose a perfect life. Welcome to visit our factory and welcome your order! For further inquiries, you should do not hesitate to contact us.