OEM Best testing of transformer Factories – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
OEM Best testing of transformer Factories – GDPD-3000C Portable Partial Discharge Detector – HV Hipot Detail:


GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time.
Specification
Hardware
● Processor: high performance intelligent processor.
● Screen: 4.3inch Touch Screen.
● Operation keys: PVE film keyboard.
● Interface:
● 3.5mm stereo headphone interface
● DC LV current charging interface
● USB 2.0 3G wireless network interface
● TF memory card interface
● External probe sensor interface
● TF memory card: 4G-32G.
● Headphones: Min. 8Ω.
● External probe: Ultrasonic probe extension line 250mm.
● Enclosures material: ABS+PC Plastique.
● Weight: 0.7kg;
● Dimension: 241*126*189mm
Operating Environment
● Operation temperature: 0~55℃.
● Operation humidity: 0~90% RH, non-condensing.
● IP rates: 54.
Ultrasonic Sensor Parameters
● Measuring range: -20dBµV~65dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Sensitivity: -65dB.
● Frequency: 40kHz.
● Diameter: 16mm.
● Test source: 25dB~35dB.
TEV Parameters
● Sensor: Capacitive.
● Measuring range: 0dBµV~60dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Max Number of Pulses/Cycle: 655.
● Min number of pulses: 5Hz
Power Supply
● Internal battery: 3.7V, 5.6Ah rechargeable Lithium-ion.
● Typical operating time: approx. 6 hours.
● Battery protection: Auto shutdown time, default 10 mins.
● Rated voltage of charger: 90-264V AC.
● Charging voltage/current: 5V/2.4A.
● Charging Time: approx. 9 hours.
Product detail pictures:
Related Product Guide:
With a positive and progressive attitude to customer's interest, our company continuously improves our product quality to meet the needs of customers and further focuses on safety, reliability, environmental requirements, and innovation of OEM Best testing of transformer Factories – GDPD-3000C Portable Partial Discharge Detector – HV Hipot , The product will supply to all over the world, such as: Niger, Korea, Bangkok, So We also continuously function. we, focuse on high quality, and are conscious of the importance of environmental protection, most of the merchandise are pollution-free, environmentally friendly products, reuse on the solution. We've Updated our catalog, which introduces our organization. n detail and covers the primary items we provide at present, You may also visit our web-site, which involves our most recent product line. We look forward to reactivating our company connection.