Partial Discharge Detector

  • GDUVI-41  UV Imager

    GDUVI-41 UV Imager

    GDUVI-41 UV imager adopts ergonomic design and key operation, which is very suitable for daily maintenance of various high-voltage electrical equipment. The instrument adopts solar-blind technology to simultaneously image the visible light and ultraviolet light paths, and realizes the location of the ultraviolet light-emitting position through the real-time synchronous fusion of the two images, which can be detected around the clock. The video display can display the ultraviolet video and the visible light video separately, or the superimposed composite video, which can count the ultraviolet light spots in the selected range and provide the measurement data.

  • GDPD-316M Handheld Partial Discharge Detector

    GDPD-316M Handheld Partial Discharge Detector

    The GDPD-316M handheld Partial Discharge Detector uses smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684781). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detection of insulating status of GIS; Ultrasonic and HFCT are suitable for detection of insulating status of power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway.

  • GDPD-505 Portable Partial Discharge Detector

    GDPD-505 Portable Partial Discharge Detector

    GDPD-505 is a portable multi-functional PD online detector, which is suitable for testing transformers, GIS, switch cabinet, power cables, lightning arrester and CT/PTs.

    The system includes detector, software, HFCT(high frequency current transformer), calibration pulse generator, 40kHz ultrasonic sensor, 150kHz ultrasonic sensor, UHF sensors, TEV sensors, Acoustoelectric sensors and some connection cables.

    It uses pulse current, ultrasonic and UHF technology, to detect and analyze HF electromagnetic signals and ultrasonic signals of internal transformers and GIS, so that to detect and evaluate the running status of GIS, transformers.

     

     

     

     

     

     

  • GD-875/877 Thermal Infrared Camera

    GD-875/877 Thermal Infrared Camera

    GD-875/877 infrared camera uses 25μm 160*120 detector, temperature measurement range -20℃–+ 350, 3.5inch TFT LCD screen.

     

     

     

  • GDPD-313P Hand-held Partial Discharge Detector

    GDPD-313P Hand-held Partial Discharge Detector

    The hand-held partial discharge detector is used to detect and measure the instantaneous ground voltage discharge and surface discharge in the switch cabinet and display the discharge waveform and discharge amount in real time on the LCD screen. The instrument adopts a pistol-portable design, which can be scanned and detected directly on the switchgear shell without any influence or damage to the operation of the switchgear. At the same time, the measured signals can be stored and played back on the TF card. The matching headphones can hear the sound of the discharge.

  • GDPD-414 Portable Partial Discharge Detector

    GDPD-414 Portable Partial Discharge Detector

    The GDPD-414 Portable Partial Discharge Detector adopts Smart Quick intelligent power test system , and is a portable local discharge inspection tool for live high voltage insulation equipment.

     

     

     

     

  • GD-610C Remote Ultrasonic Partial Discharge Detector

    GD-610C Remote Ultrasonic Partial Discharge Detector

    The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the sound of signals to diagnose faults, it is a diagnosis device for the accident of the distribution line.

     

  • GDPD-3000C Portable Partial Discharge Detector

    GDPD-3000C Portable Partial Discharge Detector

    GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge.

  • GDPD-313M Portable Partial Discharge Detector

    GDPD-313M Portable Partial Discharge Detector

    TEV and AE method is acknowledged and suitable technology to be used in online partial discharge detection. 

  • GDPD-306M Portable Ultrasonic Partial Discharge Detector

    GDPD-306M Portable Ultrasonic Partial Discharge Detector

    GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection. 

  • GDPD-414H Handheld Partial Discharge Detector

    GDPD-414H Handheld Partial Discharge Detector

    The GDPD-414H handheld Partial Discharge Detector uses smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481), which can flexibly configure various sensors according to different test objects.

     

     

Send your message to us:

Write your message here and send it to us