GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV
There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.
-
GLF-314 SF6 Gas Infrared Imaging Leak Detector
The SF6 infrared imaging leak detector is a non-contact gas imaging leak detection device that can detect possible gas leaks at several meters or tens of meters. It can quickly scan a large detection area and accurately find leaks in real time.
The gas detection thermal imager can detect the leakage or unorganized emission of organic volatiles, and still has good performance even for very small gas leakage.
The use of gas leakage detection is an efficient and reliable solution, which can detect the leakage of natural gas products in various links such as transportation, storage and production, so as to maximize safety and save costs.
-
GD6100D Insulation Oil Tan Delta Tester
In the preventive test of electrical equipment insulation, periodic measurement of insulating oil parameters of electrical equipment is required. The measurement of dielectric loss and resistivity of insulating oil is one of the most important items. For a long time, most of them have been measured by the bridge method, which is cumbersome to operate, and the measurement accuracy is affected by many factors, resulting in large measurement errors.
-
GDKC-5000 Transformer On Load Tap Changer Tester
GDKC-5000 Transformer On Load Tap Changer Tester can accurately measure the transient time, transient waveform, transient resistance, three-phase synchronization and other parameters of the load tap changer. It is an ideal device for testing load tap changer. It meets the requirements of checking the action sequence of load tap changer and measuring of switching time.
-
GD-875/877 Thermal Infrared Camera
GD-875/877 infrared camera uses 25μm 160*120 detector, temperature measurement range -20℃–+ 350℃, 3.5inch TFT LCD screen.
-
GDBT-8610P Battery Impedance Tester
GDBT-8610P is a new generation of battery tester with touch-screen. It is strictly designed to evaluate and maintain all stationary power systems including Uninterruptible Power System.
Via accurate testing of resistance and voltage, it gives an indication of battery capacity and technical status. The measurement data can be read on the instrument display directly. And it can also be uploaded to PC simply by using the USB drive. With the analyzing software, you could not only keep a record of the testing result but also have detailed analyzing for the status of batteries in different testing conditions.
-
GDPD-313P Hand-held Partial Discharge Detector
The hand-held partial discharge detector is used to detect and measure the instantaneous ground voltage discharge and surface discharge in the switch cabinet and display the discharge waveform and discharge amount in real time on the LCD screen. The instrument adopts a pistol-portable design, which can be scanned and detected directly on the switchgear shell without any influence or damage to the operation of the switchgear. At the same time, the measured signals can be stored and played back on the TF card. The matching headphones can hear the sound of the discharge.
-
GDZRS-20A Three Phase DC Winding Resistance Tester
This DC resistance quick tester (hereinafter referred to as the DC winding resistance tester) is the latest generation product for measuring the DC resistance of transformers. It is optimized for measuring the DC resistance of three-phase windings of large-capacity transformers. The DC resistance of the three-phase windings of the transformer can be tested simultaneously. For the on-load voltage regulating transformer, it is not necessary to discharge the tap changer directly, and the measurement time is one third of the traditional single-phase measurement, which can greatly shorten the working time and labor intensity. The direct resistance meter adopts a large-screen liquid crystal display, all Chinese graphical interface, clear and intuitive, and the operation is very simple. And equipped with panel printer and large-capacity non-volatile memory, you can easily store and print the measurement results. The test data is stable, fast and repeatable, and it is the best choice for measuring the DC resistance of transformers on site.
-
GDYZ-302W Metal Oxide Arrester (MOA) Tester
GDYZ-302W Metal Oxide Arrester Tester is is composed of a host, a detector, and an insulating rod. The host and the detector adopt wireless communication, the communication distance is 30 meters, the host can remotely open or close the clamp head of the detector to complete the test process, and the host can display the current test value and the status of the clamp head in real time. The detector uses a micro motor to drive the opening or closing of the clamp head. The clamp head is made of high-performance permalloy, which has super anti-interference ability and is hardly affected by external magnetic fields. The resolution is as high as 1uA. The detector can be connected to an insulating rod for testing of zinc oxide surge arresters on high-voltage lines. The meter can also be used as an ultra-high-precision clamp-on leakage current meter.
-
GDB-II Transformer Turns Ratio Tester
According to IEC and relevant national standards, the transformer ratio test is a must-do item during the production, user handover, and overhaul test of power transformers. This can effectively supervise the quality of the transformer products during delivery and use, and prevent short circuits, open circuit, wrong connection between transformer turns, and internal failure or contact failure of the regulator switch.
For this reason, the ratio tester GDB-II developed and produced by our company makes the operation easier, complete functions, stable and reliable data, and greatly improves the test speed according to the user’s on-site use requirements on the original basis. It meets the needs of various large, medium, and small oil transformer ratio tests.
-
GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)
GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection. The perfect combination of high-quality dew point sensor and intelligent electronic control technology makes it successfully applied to accurate measurement of dew point under various environmental conditions.
The dew point measurement is based on the principle of chilled mirror. The water vapor in the measured gas is condensed into water or frost on the mirror surface through semiconductor cold reactor cooling. When the two-phase equilibrium of water in the gas is reached, the temperature of the mirror surface is measured at this time, that is the dew point or frost point.
Compared with other forms of dew point meter, the chilled mirror dew point meter measures the dew point temperature more accurately, and at the same time has the characteristics of good measurement repeatability, stable and reliable measurement results, and easy operation.
GDP-713PM portable cooling method SF6 gas dew point meter is a standard instrument for humidity measurement in the fields of electric power, gas, meteorology, electronics, petroleum, chemical industry, measurement, etc. It is an ideal choice for establishing a humidity standard device.
-
GDQH-31H Portable SF6 Gas Recovery Device
GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.
At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV.