Partial Discharge Test System GIT series
GIT series is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.
-
GDCY Impulse Voltage Test System (100kV-7200kV)
Impulse Voltage Test System is mainly used for carrying out full wave lightning impulse voltage test, chopping impulse test and switching impulse test on HV apparatus such as transformers, surge arrester, insulators, bushings, capacitors, and switches. It can generate standard lightning wave, switching wave, chopping wave with wide range voltage and energy.
-
Partial Discharge Test System GDYT series
It widely used in electrical manufacturing, power operation departments, research institutes and universities.
-
PD Free Variable Frequency Test System
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider.
-
AC High Voltage Test Sets for GIS
AC Resonant Test System for Substation Electrical Equipment, is mainly composed of variable frequency power supply, Excitation Transformers, Reactors, Capacitive dividers, which designed for AC withstand voltage test of substation electric equipment at 500kV or below.
-
GDBT Series Transformer Test Bench
GDBT Transformer test system can conduct all routine tests for transformers, including No-load and load test, Induced voltage test, Power frequency withstand voltage test, partial discharge test, DC resistance test, turns ratio test, temperature rising test etc.
-
GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test
GDSL-A Series 3-phase Primary Current Injection Test Set with Temperature Test is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy use and maintenance.
-
GDW-106 Intelligent Oil Dew Point Meter&Micro-Moisture Tester
The warranty period for this series is ONE year from the date of shipment, please refer to your invoice or shipping documents to determine appropriate warranty dates. HVHIPOT corporation warrants to the original purchaser that this product will be free from defects in material and workmanship under normal use.
-
GDZL-503 Automatic Interfacial Tension tester
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.
-
GDZD-601 Automatic Multi-Function Insulation Oil Shaker
Multi-Function Shaker is used in laboratory to test heat, shake, degas various kinds of liquid under constant temperature and a fixed time. It is controlled by micro-computer to realize man-machine interaction.
-
GDYN-901 Kinematic viscosity tester
GDYN901 is suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity.
-
GDND-800 Freezing Point Tester
Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products.