Technical Guide
-
Application Scope and Selection of 0.1Hz Ultra-Low Frequency High Voltage Generator
The 0.1Hz ultra-low frequency high-voltage generator is an instrument specifically designed for insulation withstand voltage tests of power equipment, especially suitable for large-capacitance devices such as power cables and large generators. This device replaces the traditional 50Hz power frequ...Read more -
Main Functions and Usage of Switch Mechanical Characteristic Tester
The switch mechanical characteristic tester is a high-precision specialized instrument used for testing the mechanical dynamic characteristics of high-voltage circuit breakers. It is of great significance in the power system. The performance of the circuit breaker directly affects the safe operat...Read more -
Transformer off-line partial discharge detection methods and test equipment
Overall Composition of the Detection System To conduct off-line partial discharge detection on transformers, a complete high-voltage test circuit needs to be set up. According to the detection functions and principles, the instruments and equipment are divided into two categories: the pulse curre...Read more -
The application scope of different types of insulation resistance testers
The insulation resistance of all electrical devices and equipment must comply with the requirements of relevant norms and standards to ensure safety during on-site operation. Whether it is electrical cables, sectional protection equipment, or motors, generators, etc., the electrical conductor par...Read more -
The Usage Method and Precautions of the Battery Charge and Discharge Tester
The usage method of the battery charge and discharge tester: Preparation before testing: Connect the battery to the battery charge and discharge tester correctly and set the test parameters. Charging test: Charge the battery through the charging function, and test parameters such as charging ti...Read more -
Transformer Ratio and Polarity Tester: Test Wiring and Usage Method
Transformer Ratio Polarity Tester Wiring Instructions Voltage Transformer Test: The “output” terminal of the instrument is connected to the A terminal on the high-voltage side of the voltage transformer. 2) The “output” terminal of the instrument is connected to the X t...Read more -
The on-site measurement operation method of the digital dual-clamp phase voltmeter
Operation and Use of Digital Dual-Clamp Phase Volt-Ampere Meter Press the ON-OFF button and rotate the function range switch to correctly select the test parameters and range. Measure AC voltage Set the function range switch to the 500V range corresponding to parameter U1, and input the measur...Read more -
Operation Method of Transformer Core Grounding Current Tester Interface
Press the POWER button to turn on the device. The LCD will display the function menu page. If the LCD keeps flickering black after startup, it might be due to insufficient battery voltage. Please replace the battery and then press the POWER button to shut down the device. After 30 minutes of star...Read more -
On-site Cable Fault Testing Instructions for Power Cable Fault Tester
Digital ground resistance testers are indispensable tools in electrical safety inspection, lightning protection grounding projects, and other fields. The following is a summary from three aspects: classification, application, and key points for selection. I. Classification According to the measur...Read more -
Classification and Application of Power Engineering Testing Equipment
The instruments and equipment used in power engineering testing are diverse in types. According to their functions and application scenarios, they can be classified into five major categories, each of which includes typical instruments and core application scenarios. 1. Insulation and Electrical ...Read more -
Application and Selection of Circuit Breaker Loop Resistance Tester
I. Product Classification (1) Classification by Technical Principle DC Voltage Drop Method (Four-Wire Method / Kelvin Method) Tester Principle: It uses the four-terminal measurement method, applying a stable DC current (usually ≥100A) to the circuit under test and calculating the resistance value...Read more -
The test principle and on-site test method of SF6 micro-water tester
Classification of measurement methods for SF6 The measurement methods for the moisture content of SF6 gas are classified into three types based on different principles: electrolysis method, dew point method and capacitance-resistance method. 1) Electrolysis method. This method uses the Coulomb ...Read more