  • Why test the dielectric strength of insulating oil?

    Why test the dielectric strength of insulating oil?

    The main reason for testing the dielectric strength of insulating oil is that the dielectric strength of insulating oil is an important index reflecting the quality of insulating oil, and this index can directly reflect the withstand voltage capability of insulating oil. The dielectric strength o...
    Read more
  • What are the requirements for DC resistance tester to detect power transformers

    What are the requirements for DC resistance tester to detect power transformers

    For power transformers with a voltage level of 10KV and below, the detection requirements in the winding DC resistance test item are: the transformer is 1.6MVA and below, and the requirements for phase-to-phase difference regulations: it should not be greater than 4% of the average value of the t...
    Read more
  • Common problems and solutions in transformer high voltage test

    Common problems and solutions in transformer high voltage test

    In the high-voltage test of transformers, many key points should be paid attention to, and the test conditions and test methods must be accurately grasped. The faults that occur in the high voltage test of the transformer should be screened one by one, and the faults should be properly handled. E...
    Read more
  • Common troubleshooting methods of Capacitance and Tan Delta tester

    Common troubleshooting methods of Capacitance and Tan Delta tester

    It is inevitable that the test data of the high-voltage dielectric loss tester will be obviously unreasonable during use. Once this positive problem occurs, the reason can be found from the following aspects: 1. Poor contact of the hook When using a hook to connect the test object for on-site mea...
    Read more
  • Electrical safety common sense training

    Electrical equipment will not endanger human health and surrounding equipment during normal operation and under expected abnormal conditions. When electrical equipment fails unexpectedly, it should be able to cut off the power supply and limit the accident within the allowable range. If electrica...
    Read more
  • Measuring principle of transformer on-line monitoring

    Measuring principle of transformer on-line monitoring

    One of the effective methods for on-line detection of transformer insulation is to monitor the parameters of partial discharge electric pulses. In the normal operation of the transformer, the partial discharge is small. In recent years, the partial discharge of the transformers above 110kV produc...
    Read more
  • The use range and precautions of Insulating Hipot Gloves (boots) Test Set

    The use range and precautions of Insulating Hipot Gloves (boots) Test Set

    The new standard stipulates that electrically insulating shoes shall be used as safety aids for electrical work. As an occupational safety manager, you should clearly understand this. Usually, managers with insufficient electrical knowledge will mistakenly think that 6kV insulated leather shoes o...
    Read more
  • Precautions for Series Resonance Test System

    Precautions for Series Resonance Test System

    Precautions for Series Resonance Test Syetem 1. During the test, the test phase is connected to the high-voltage source, and the high-voltage lead wire needs to use a special halo-free lead wire, and the non-test phase is grounded with the GIS shell; 2. The test must ensure that the SF6 gas in ea...
    Read more
  • How to effectively prevent overvoltage problems during substation operation

    How to effectively prevent overvoltage problems during substation operation

    In the process of operating the no-load transformer, there will be an unavoidable physical phenomenon, that is, cut-off. The problem of operating overvoltage due to the cut-off of the circuit breaker can be prevented by taking the following measures: 1. Improve the iron core Improving the iron co...
    Read more
  • How to measure the dielectric loss of transformer

    How to measure the dielectric loss of transformer

    First of all, we can understand that the dielectric loss is that the dielectric is under the action of an electric field. Because of the internal heating, it will convert electrical energy into heat energy and consume it. This part of the consumed energy is called dielectric loss. Dielectric loss...
    Read more
  • The difference between the DC withstand voltage test device and the AC withstand voltage test device

    The difference between the DC withstand voltage test device and the AC withstand voltage test device

    1. Different in nature AC withstand voltage test device: the most effective and direct method to identify the insulation strength of electrical equipment. DC withstand voltage test device: to detect the relatively large peak voltage that the equipment withstands under the high voltage test. 2. Di...
    Read more
  • What are the factors affecting the results of the series resonance test?

    What are the factors affecting the results of the series resonance test?

    Even with the so-called “all-powerful” series resonance, the test results will still be affected by uncertain factors, including: 1. The influence of weather In the case of high humidity, the corona loss of the lead wire increases greatly, and the interference of the surrounding elect...
    Read more