-
China High Quality Blocking Cap Factory – VLF AC Hipot Test Set – HV Hipot
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal... -
China High Quality Vacuum Circuit Breaker Testing Manufacturer – GDSL-BX-200 Primary Current Injection Test Set – HV Hipot
Features ● Digital control, high anti reference ability. ● Adapts autotransformer regulator which with low power consumption and large capacitance. ● Converter has high permeability core. ● Quick connects, lock design, have good current capability. ● PVC panel. ● Build-in quick plug with high safety. ● Current range can be changed, easy to read. ● Engineering plastics box, IP67 dustproof and waterproof. ● Portable design is suitable for on-site testing. ● Zero start function to prevent the test objects from damage caused by high current impulsing. The equipment only can be started at zero. ● Impulse choosing function: The current value can be outputted directly without zero protection function when the equipment is under the testing for circuit breaker. ● 0-50A AC current can be outp... -
OEM Best Voltage And Pluse Generator Factory – GDCY-300kV/30kJ Impulse Voltage Test System – HV Hipot
Application This impulse test system is used for carrying out full wave lightning impulse voltage tests on HV apparatus such as clearance, bushings, capacitors, switches, power transformers(capacity below 5000kVA), CT/PT at 35kV or below. Operating Condition ● Altitude: 1000m. ● Ambient Temperature: -5℃~+45℃. ● Max. daily difference temperature: ≤25℃. ● Relative humidity: <90%. ● Anti-shock ability: ≤ level 7. ● Horizontal acceleration of the ground: 3.0m/s2, Vertical acceleration of the ground: 1.5m/s2. ● Waveform of power supply voltage wave is sine actually, and the waveform distortion rate<3%. ● It should be grounded reliably, ground resistance <0.5Ω. ● Usage environment: indoor. No conductive dust, No fire and explosion, No corrosive metal and insulation gas. Applied Sta... -
China High Quality used megger for sale Exporters – Online Insulation Monitoring Device for DC System – HV Hipot
General Information GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance. It does not produce any AC or DC interference signal to busbar, and will not cause the artificial insulation resistance drop. It is suitable for power plants and substations of any voltage level. GDF-5000/OL’s unique stability and anti-distributed capacitance make it more suitable for bus system under complex working conditions, standard instrument structure, compact size, convenient installation and better applicability. GDF-5000/OL has LCD display, full software function control, perfect man-machine interface, easy operation and use. Features ● ... -
China High Quality Oil dew point Supplier – GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator) – HV Hipot
Coulometric Karl Fischer technology is applied to measure precisely trace moisture the measured sample contains.The technology is widely used for accuracy and cheap test cost.The Model GDW-102 measure precisely trace moisture on liquid, solid and gas samples according to the technology. It’s used in electricity, petroleum, chemicals, foods and so on. Features ● Use improved PWM electrolysis circuit to reduce the power dissipation of the instrument. ● High precise measuring electrode signal and circuit detection make the electrolytic end decision quickly and precisely with strong anti-interference ability. ● Use methods of electrolyte blank current compensation and electrolyte balance drift compensation to devise testing result. ● Built in three calculation formula to generate r... -
OEM Best dew point test set manyfacturers Factory – GDZL-50L Oil Filtration Machine – HV Hipot
General Information The machine GDZL-50L can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, to ensure the safe operation of the power equipment. It is mainly used in the power sector and industrial and mining enterprises to deal with unqualified transformer oil, transformer oil, switch oil and so on. Features ● Small size and high efficiency, easy to move. It is especially suitable for live working on site. It also can dry the moisture of power equipment, and conveniently vacuum the power equipment. ● Infrared liquid level automatic control device, system pressure automatic protection device and high-efficiency degassing components are adopted in the structure. The operation is convenient and ... -
China High Quality Contact Resistance Test Factories – GDHL-100A Micro-Ohmmeter – HV Hipot
General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance; ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● Multiple test times can be set, which meets various on-site applications; ● Large current output for a long time, burning the switch ... -
China High Quality Current Transformer Suppliers – GDHG-201P CT/PT Analyzer – HV Hipot
Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of... -
OEM Best Capacitor Discharge Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot
Application Features ● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Continuously variable output from zero to full voltage. ● Adjustable over current protection, with trip levels variable from 10 to 110%. ● With new type time relay, time range is wider (1S ~ 99H). ● Using the latest current relay, more accurate and reliable. ● Light weight, small size, easy to move. Technical Specifications ● Input voltage: AC 220V or 380V ● Output voltage of control unit: AC 0-250V or 0-430V ● Output current of control unit:0-5/10/15/50A(customized) ● Ca... -
China High Quality 15 kv high voltage insulation resistance tester Manufacturer – GD2000H 10kV Insulation Resistance Tester – HV Hipot
General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut... -
OEM Best Under Ground Cable Identifier Supplier – GD-2134E Cable Identifier – HV Hipot
GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta... -
OEM Best Discharge Ac Capacitor With Multimeter Manufacturers – Partial Discharge Test System GDYT series – HV Hipot
GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space. There are two modes to generate high voltage 1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object. 2) The other one is to obtain required high voltage directly from high voltage transformer. It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer. Features ● The High voltage o...