GD2000H 10kV Insulation Resistance Tester

GD2000H 10kV Insulation Resistance Tester

Brief Description:

This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components.


Product Detail

Product Tags

General Information

This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components.
It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors' insulation.
Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can't be found before failure happened. In EU, this test is compulsory, even to civil system.

Features

1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ.
2. Two modes display insulation resistance.
3. Auto-calculating absorption ratio and polarization index.
4. Friendly operation, continuous saving 19times measurement results.
5. Auto-discharge residual high voltage after test is over.
6. AC/DC power supply, with rechargeable battery or AC adapter.
7. Strong anti-interference ability, stable and reliable reading.
8. Portable design, suitable for wild work.
9. Short-circuit current ≥3.5mA, ideal equipment for testing insulation resistance of large transformer, inductor, generator, HV motors, electric capacitor, cables and surge arrester.

Technical Specifications

Item Model

GD2000H

Output voltage

5kV DC

10kV DC

Accuracy

Temperature

23℃±5℃

Insulation resistance

5M ~ 100G

±5%

10M ~ 200G

±5%

Other range: ±10%

Output voltage

40M ~ 200G

0 ~ +10% 

80M-400GΩ

0 --+10%

Short-circuit current

≥3.5mA

Power supply

8 * AA type high capacity rechargeable battery & external adapter

Working Temp.& Humidity

-10℃--40℃,max.relative humidity 85%

Storage Temp.& Humidity

-20℃--60℃,max.relative humidity 90%

Insulation

Max.20000MΩ when voltage between circuit and shell is 1000VDC.

Withstand voltage

Withstand 1min when voltage between circuit and shell is 3kV /50Hz AC

Dimension

230mm*190mm*90mm  (L*W*H)

Weight

3kg

Accessories

Test leads, manual, rechargeable adapter, power cable, test report

Accessories
Insulation resistance tester 1set
Test wire 1piece                   
Power adapter 1piece               
Power cord  1piece                
User’s Guide 1copy                   
Certificate 1copy               