GDCR1800A Wireless High Voltage Detector

GDCR1800A Wireless High Voltage Detector

Brief Description:

GDCR1800 series wireless high voltage tester (with voltage and current indication) is specially designed and manufactured for high voltage transmission line inspection, high voltage transmission line to ground voltage, induced voltage test and current test. This instrument can test the high-voltage to ground at the same time as the alarm of the power check.

GDCR1800 series wireless high voltage electroscopes have a voltage level of 0.1kV ~ 220kV, which completely covers the power and ground voltage test of each voltage level (3kV, 6.3kV, 10kV, 35kV, 66kV, 110kV, 220kV). which is safe, reliable and saves time. It is an indispensable tool for power transmission line maintenance. During the inspection and maintenance of the transmission line, even if the line has been disconnected, due to the capacitive effect, there may still be very high voltage through induction, which seriously threatens the safety of the operator and the operating process. Make sure the voltage has dropped to a safe and operational voltage level.


Product Detail

Product Tags

Specifications

Function

Wireless high voltage power test, high voltage and induced voltage test,
high and low voltage current test

Power supply

Receiver: DC6V, 4* AA alkaline batteries
Detector: Zinc-manganese dry battery 6F22, 9V

Transmission distance

Wireless transmission, linear transmission distance of about 30 meters

Test voltage range

380V~220KV

Voltage level display

380V、6.6KV、10KV、35KV、66KV、110KV、220KV

Ground voltage display range

0.1KV~150KV(to ground voltage)

Ground voltage display accuracy

High voltage overhead line ± 15% ± 5dgt (Other applications: ± 25% ±
5dgt)

*Current range

0.1A~6000A(Only type B)

*Current accuracy

±3%±5dgt(Only type B)

*Current resolution

0.1A(Only type B)

Hook size

φ50mm(GDCR1800A);φ60mm(GDCR1800B)

Probe length

110mm(Only for GDCR1800A)

Wireless frequency

433MHz

LCD size

47mm×28.5mm

Power indicator

Green power indicator

Electricity inspection
instructions

The detector has sound and light indication function during electricity
inspection, red double flashing light indication and "beep-beep-beep"

Display rate

2 times / second

Data storage

99 groups (data will not be lost if power is lost or battery replaced)

LCD backlight

With backlight

Automatic shutdown

The instrument will automatically shut down after 15 minutes

Low battery voltage indication

When the detector battery voltage drops below 7.2V ± 0.1V, the green power indicator flashes; when the receiver voltage is lower than 4.8V ±0.1V, the battery voltage low symbol "     " is displayed to remind the
battery replacement.

Rated current

Detector:75mA max;Receiver:35mA max

Communication interface

USB

Weight

660g (including battery); total: about 5.6kg

Size

Receiver:78mm×165mm×42mm;Detector:300mm×273mm×85mm

Insulation rod length

Maximum diameter Φ38mm; Length: 850mm in contracted state;3600mm in extended state

Insulation test

Both ends of insulated rod after stretching: AC 220kV / rms
Receiver and detector: AC3700V / rms (between exposed metal and plastic case)

External interference

No extra strong electromagnetic field; no 433MHz co-frequency interference at the test site

Working temperature and
humidity

-10℃~40℃;below 80%rh

Storage temperature and
humidity

-10℃~60℃;below 70%rh