OEM Best megger tester for sale Suppliers – Substation Temperature Monitoring System – HV Hipot

OEM Best megger tester for sale Suppliers – Substation Temperature Monitoring System – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

It is a great way to further improve our products and repair. Our mission is always to create innovative products to prospects with a superior expertise for Partial Discharge Test On Transformer, Dielectric Strength Testing, Power Transformer Distribution Transformer, On account of superior quality and competitive price , we will be the market leader, please don’t hesitate to contact us by phone or email, if you are interested in any of our products.
OEM Best megger tester for sale Suppliers – Substation Temperature Monitoring System – HV Hipot Detail:

General Information

There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in time, so as to prolong the pretest period of power failure and completely replace on-line monitoring method.

GDDJ-HVC dielectric loss tester for live capacitive equipment can be used to measure dielectric loss and capacitance of capacitive equipment (bushing, CT, CVT, coupling capacitor), and detect insulation flaws effectively.

Features

1. External hole type current sensor with high precision is often used instead of the traditional sampling unit, which includes more than one switch circuit. During testing, multiple short tabs are needed to lead end shielding current to test instrument. GDDJ – HVC uses traditional straight-through structure, can be installed near the equipment, lead of end shielding is not broken and the length is very short, which avoid open circuit of end shielding. The sensor can accurately detect signals within 100μA~700mA. Impedance of sensor is low, can withstand power frequency current 10A and lightning impulse current 10kA, meet use conditions of online detection.

2. The sampling unit adopts die-casting aluminum shell sealing waterproof design, and adopts waterproof cable connector for secondary output, which is convenient for connection; After the sensor is installed, it is normally not energized. For testing, only the secondary cable of the sampling unit need be connected, and “plug and play” can be achieved without any operation on the end shielding signal cable.

3. The core processor of the instrument is American TI 32-bit floating-point high performance digital signal processor (DSP), which runs a real-time operating system and adopts an extended 16-bit, high-speed, multi-channel synchronous sampling analog digital converter (A/D) to realize real-time measurement and high-precision calculation of the monitored quantity. Able to monitor multiple devices simultaneously.

4. Two on-line detection methods for dielectric loss can be provided, which can measure dielectric loss difference and capacitance ratio of two capacitive devices in the same phase, and PT secondary voltage can be used as the reference signal to measure the capacitance and dielectric loss of the device. Using the compensating current sensor and advanced digital filtering technology, the problem of dielectric loss precision and stability is solved, combined with perfect electromagnetic shielding measures and advanced processing technology, digital filtering can ensure dielectric loss test results are not affected by the influence of harmonic interference and pulse interference, with absolute precision up to ±0.05%.

5. With the detection of dielectric loss difference and capacitance ratio of in-phase capacitive equipment, it can not only avoid the distortion of dielectric loss test result caused by using PT secondary voltage as the reference signal, but also help to reduce the influence of phase-to-phase electric field interference.

6. The detector is equipped with a large LCD screen for displaying the monitored voltage, current, dielectric loss, resistive current, capacitive current and other data.

7. The tester not only has the function of live detection, but also can monitor the equipment online for a long time, and automatically record the monitored data.

8. The system adopts external sensors instead of “traditional sampling unit”, which can be easily upgraded from “live detection” to “online monitoring” under normal operation of the equipment. There is no need to remove the installed sensors, no need to disable the device, just add a monitoring unit (IED).

9. The detector adopts portable design, simple to operate, the lithium battery in the machine can maintain 8 hours of continuous working time, fully meet the requirements of field use.

Specification

Main unit
Power supply Maintenance-free battery
Cable 30m, 2 pieces
Ambient temperature -45~60℃
Display Large screen LCD display, suitable for outdoor use.
Size 430*340*160mm
Weight 5kg
Measurement range & accuracy
Current Cx=100μA~1000mA, Cn=100μA~1000mAAccuracy: ±(0.5%+1digit)
Voltage Vn=3V~300V
Accuracy: ±(0.5%+1 digit)
Dielectric loss Tanδ= -200%~200%
Accuracy: ±0.05%
Capacitance ratio Cx: Cn=1:1000~1000:1
Accuracy: ±(0.5%C+1 digit)
 
Capacitance
Cx=10pF~0.3μF
Accuracy: ±(0.5%C+2pF)
Note: actual measurement accuracy is related with current of test object and accuracy of PT (or CVT) in use.
Resistive current Irp=10μA~200mA (peak)
Accuracy: ±(0.5%+1digit)
Capacitive current Icp=10μA~200mA
Accuracy: ±(0.5%+1digit)
Other characteristics
Harmonic suppression Waveform distortion of input current signal will not affect the measurement accuracy.
 Power management
 
When the battery power in the machine is low or has not been measured for a long time, it will give sound alarm and automatically shut down.
Charging time 12~24 hours in shutdown state, intelligent charging system, power-off protection after fully charge.

Product detail pictures:

OEM Best megger tester for sale Suppliers –  Substation Temperature Monitoring System – HV Hipot detail pictures


Related Product Guide:

We can easily usually fulfill our respected customers with our very good top quality, very good price tag and excellent support due to we have been more expert and much more hard-working and do it in cost-effective way for OEM Best megger tester for sale Suppliers – Substation Temperature Monitoring System – HV Hipot , The product will supply to all over the world, such as: Amman, Swaziland, Belgium, Our company now has many department, and there have more than 20 employees in our company. We set up sales shop, show room, and product warehouse. In the meantime, we registered our own brand. We have tightened inspection for quality of product.
  • Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Cora from Swaziland - 2018.03.03 13:09
    It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Elma from Latvia - 2017.07.07 13:00

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us